The inducer is the small fan that runs on its own for half a minute before any gas comes on, pulling the exhaust out through the flue. Because a pressure switch is listening to it, a tired inducer usually reports itself as a switch fault, and the noise it makes tells you which part of it has gone.
The inducer is the easiest part of a furnace to hear and one of the least understood. It is the small fan that spins up on its own at the start of every cycle, thirty seconds or so before anything lights.
Its job is to pull the exhaust out through the flue, and because another part is listening to whether it managed that, a failing inducer very often shows up as something else entirely.
Before you start
What to carry: a torch and a screwdriver. Ten minutes of listening.
Gas or electric? Only fuel burning furnaces have one, because only they have an exhaust to pull. If your furnace has a thick cable and no flue, there is no inducer in it.
Listen to it start. Turn the thermostat up and stand at the furnace. The first thing to move is the inducer, and you can judge most of this page by ear before opening anything.
And do not run a furnace with the inducer housing loose or its gasket missing. That housing is part of the sealed path the exhaust travels along. A leak there puts flue gas into the furnace cabinet, and the cabinet is in your house: what that means and what it smells like.
Where it sits and why that matters
Work out whether it is the motor or the message
The sequence on every modern furnace is the same. The inducer runs first and creates suction in the flue. A thin hose carries that suction to the pressure switch. If the switch is satisfied, ignition is allowed.
So a weak inducer produces a pressure switch code. The board is not wrong and the switch is not wrong. The fan simply did not pull hard enough.
It runs, then everything stops. That is the typical picture. Before buying a motor, work through the cheap causes of the same symptom, because a blocked drain gives you exactly this: the five places to look first.
It does not run at all. Then it is either the motor, its capacitor, or the board not calling for it. Check the board is getting as far as trying.
What each noise means
Name the noise before you open anything
A whine that has got worse over a season. Bearings. They do not recover, they get louder, and eventually the motor seizes. It is a common way for one to fail.
A rattle only in the first second or two. Usually the wheel rather than the motor. A wheel that has loosened on its shaft, or debris caught in it, or a mounting grommet that has perished.
Grinding. The bearings have gone. Off at the switch.
A buzz with no movement. Either seized, or on the motors that have one, the small run capacitor has failed. A seized motor and a dead capacitor sound identical from outside.
A whistle or a hiss rather than a mechanical noise. That is usually air rather than the motor, through a cracked housing or a gasket that has gone hard, and it shows up as poor draught.
What it costs, and whether to bother
Price it against the furnace
The part. Many inducers come as a motor and housing together.
Fitted. Three to six hundred, because it is an hour’s work and the gasket has to seat properly.
Doing it yourself. Mechanically it is a few screws, a plug and a hose. What makes it different from changing a filter is that it is part of a sealed combustion path, so the gasket, the hose routing and the drain connection all have to go back exactly right.
On an old furnace. An inducer repair on a twenty year old furnace is worth thinking about rather than refusing outright, because a working inducer is not the part that decides how long the furnace lasts. What decides that is the heat exchanger.
If the same motor fails twice. Look at why. Water sitting in the housing from a blocked drain kills inducers, and fitting a third one without clearing the drain is money thrown away: where that water comes from.
Questions people ask
It starts and stops, over and over.
That is the board giving up waiting for the pressure switch, then trying again. The inducer is a suspect, and so are the four cheaper things ahead of it.
Can I oil it to quieten it down?
Almost all of them are sealed, so there is nowhere for oil to go. A whine that has appeared is the bearing telling you its remaining life, not asking for oil.
How long should one last?
Often the life of the furnace, which is why a failure at eight or ten years is worth asking about. Water in the housing and a furnace that short cycles both shorten it considerably.
Mine is noisy but the furnace works fine.
Then you have warning, which is the good version of this. Plan it rather than waiting for the first cold snap, because that is when it will actually stop.
Is it the same as the blower?
No. The inducer is small and moves exhaust. The blower is large and moves the air in your house: which kind of blower you have.
Could a dirty flue be damaging it?
Yes, because the motor works harder against a restriction. Clearing the flue and the pipes outside is worth doing at the same time as any inducer work.
Sources: Carrier 58SC0A/58SC1A instructions (prepurge and igniter warm-up, code 31 causes), Goodman *MSS9 (GMSS96) installation instructions (15 second prepurge, pressure taps on the inducer, permanently lubricated inducer bearings, blocked drain or weak inducer), and White-Rodgers 50M56U-843 instructions (30 second pre-purge)