Free, independent repair guides
HeatCoolFix

Honeywell S8910U Error Codes: Match the LED Chart

Honeywell S8910U Error Codes: Match the LED Chart
Short answer

Honeywell S8910U error codes depend on the control version. Resideo's older instructions give 1 flash for ignition lockout, 2 for weak flame and 3 for an internal error. The S8910U3000 uses a different chart with red, yellow and green states. Match the label before interpreting a count.

Honeywell S8910U error codes need the right version of Resideo’s instructions beside them. A flash count alone can send you toward the wrong fault: the older chart calls two flashes a weak flame signal, while the S8910U3000 chart calls two yellow flashes low input voltage.

Start with the module’s full label or its installation paperwork. This is a guide to the light and the heating sequence, with the service tests kept for the person repairing it.

Before you start

What to carry: a torch, your appliance paperwork and a phone to record a light that is already safely visible. Leave the service cover closed if opening it would expose wiring or the burner.

Gas or electric? Resideo describes the S8910U as a direct ignition control for natural or LP gas, using a 120 volt hot surface igniter. It does not control an all electric furnace. Nor is it the intermittent pilot control covered in our Honeywell S8610U guide.

Renting? Send maintenance the appliance model, the module model if you already have it, and the light’s color and pattern. You do not need to uncover the board to make that report.

Record it before resetting. Both Resideo manuals say the LED reports the current call for heat. Ending that call or switching off system power loses the status information.

Gas, a wet module and exposed wiring.
Resideo says that if you smell gas or suspect a leak, turn off gas at the manual service valve and evacuate the building. Do not try to light an appliance or touch an electrical switch or telephone inside until the area is free of gas. Get help from outside.

Resideo also says never to use a module that has been wet, and not to disassemble or clean the module. Its instructions reserve hot surface ignition service for trained, experienced technicians and require power disconnected before wiring work. Keep electrical measurements, gas adjustments and igniter handling out of your checks.

Which S8910U chart belongs to yours?

Resideo’s older form 69-0845-03 describes a control configured with selection tabs. Its status chart has a heartbeat and one, two or three flashes. The S8910U3000 instructions, form 34-00008EFS-03, use DIP switch settings and a table that includes color as well as pattern.

MATCH THE INSTRUCTIONS FIRST A Older form 69-0845-03 Selection tabs; heartbeat or 1, 2, 3 flashes B S8910U3000, form 34-00008EFS-03 DIP switches; record color and pattern
Two versions of Resideo's instructions, shown as simplified controls. A matches the older selection tab instructions. B matches the S8910U3000 instructions. Use paperwork or an existing service record to identify yours without exposing the wiring.

If you searched for S8910U1000, do not choose a chart just because a search result says S8910U. Have service match the full part number and the instructions supplied with the installed control. The two charts below are deliberately kept separate.

Older instructions, 69-0845-03 Resideo’s meaning
Pulsing heartbeat Normal operation during a call for heat, including the stages before the burner runs
1 flash Ignition lockout
2 flashes Weak flame rectification signal
3 flashes Internal error
S8910U3000 LED, 34-00008EFS-03 Table 6 Resideo’s meaning
Red, steady Device locked after detecting a welded gas valve relay; replace the control
Red, intermittent blink Hard lockout after exceeding the maximum retries
Yellow, steady Soft lockout from gas valve failure or eight consecutive recoverable lockouts; next ignition attempt after one hour
Yellow, 1 flash Flame detected out of sequence
Yellow, 2 flashes Recoverable lockout from low input voltage
Yellow, 3 flashes Recoverable lockout from AC line frequency outside the acceptable range
Yellow, 4 flashes Recoverable lockout from an internal error
Green, steady Normal sequence and operation
Green, intermittent blink Normal sequence and operation, with a weak flame detected

What the light and the burner tell you

Check 1An observation from outside the closed appliance

Normal light: note which stage stops

Resideo’s S8910U3000 sequence starts with prepurge, then warms the igniter with the gas control closed. The gas control opens for the ignition trial, and flame sensing determines whether the burner can keep running. A steady green light covers those normal stages; it does not mean the burner is already alight.

If you can see the burner through an existing viewing window, note whether it never lights or lights and then goes out. Do not remove a door or defeat its safety switch to watch. That simple difference helps service use Resideo’s troubleshooting paths.

Check 2A technician checks the ignition sequence and gas supply

Ignition lockout: separate failure to light from failure to stay lit

For the older chart’s one flash, Resideo lists a burner that failed to light or a flame that was not detected. Its service path for no ignition includes the gas supply, input voltage, igniter, gas control and wiring.

For a burner that lights but dies at the end of the trial, Resideo instead points service toward the igniter or sensor, flame rod, burner ground and wiring. Report what you saw rather than ordering a new igniter from the code alone.

On the S8910U3000, intermittent red means the control has run out of ignition retries. Its steady yellow soft lockout is a different state with the one hour wait in Table 6.

WHAT HAPPENED AT THE BURNER? A Never lights Service follows the no ignition path. B Lights, then dies at the end of the trial Service follows the flame sensing path.
Resideo separates a burner that never lights from one that lights but goes out at the end of the ignition trial. These are observations through an existing window, not instructions to open the appliance or test live parts.
Check 3Flame sensing, grounding and gas pressure checks by service

Weak flame: keep the version attached to the report

Resideo gives two flashes in the older chart, or intermittent green in the S8910U3000 chart, for a weak flame signal. Its possible causes include a contaminated or misplaced igniter or flame rod, poor flame sense wiring insulation or connections, and poor gas pressure.

Our furnace flame sensor guide explains the role of flame detection in more detail.

Check 4Electrical diagnosis, with control replacement where the manual requires it

Internal, supply and relay faults need their own service path

For the older chart’s three flashes, Resideo says to start a new call for heat and replace the control if the signal returns. For four yellow flashes on the S8910U3000, its procedure includes a new heat call, then a wait of one to two hours if the error returns, followed by another try.

Resideo calls for replacement if that S8910U3000 internal error returns again. Leave that diagnosis to service. Two or three yellow flashes belong to voltage or line frequency checks, respectively, rather than the older weak flame and internal error meanings.

For steady red on the S8910U3000, Resideo explicitly calls for control replacement because a welded gas valve relay was detected. Arrange service instead of trying to clear that state with thermostat changes. Report one yellow flash as unexpected flame, also for professional investigation.

What a reset can do

Resideo’s S8910U3000 safety shutdown instructions give a manual reset by removing power or setting the thermostat below room temperature for at least 30 seconds. If the appliance’s own user instructions permit a thermostat restart, follow those after recording the light and ruling out the warning conditions above.

The number of ignition attempts is set by the installed configuration: Resideo describes both one trial and three trial operation. Do not change selection tabs or DIP switches to get more attempts. If the fault comes back, send the original pattern and the new result to service.

What each one takes

Finding Work involved
Uncertain control version Matching paperwork or a service record to the installed module
Ignition lockout Professional checks of the failed stage
Weak flame indication Flame sensing, wiring, grounding and gas pressure diagnosis
S8910U3000 supply fault Voltage or line frequency measurements by service
Recurring internal error or steady red relay fault The manual’s service procedure and possible control replacement

Questions people ask

Can I use an S8610U blink chart?

No. Resideo’s S8910U instructions exclude intermittent pilot ignition controls. This page concerns the S8910U hot surface ignition family.

Where are the S8910U manuals?

Resideo hosts the older S8910U instructions and the S8910U3000 instructions. Match the installed module before choosing between them.

Does a normal light prove the whole furnace is working?

Resideo’s normal indications cover prepurge and igniter warmup as well as burner operation. Note the stage reached and whether heat arrives at the rooms.

Is a replacement control chosen by the furnace brand?

Resideo requires a match to its replacement tables and the specified configuration. Have the technician verify the old control and the appliance instructions before choosing a replacement.

Can a wet module be dried and reused?

Resideo says to replace a module that is wet or appears to have been wet. Drying it does not meet that instruction.

The other ignition control guides: Honeywell S9200 furnace codes, Honeywell SmartValve flash codes and White-Rodgers 50D50U error codes.

Sources: Resideo installation instructions 69-0845-03, S8910U Universal Hot Surface Ignition Module, pages 14 and 15; and 34-00008EFS-03, S8910U3000, English pages 1 and 15 to 19, including Table 6