On Napoleon's 9600 B control, one red flash means an open high limit, two mean a pressure switch open with the inducer on, and four mean a one hour lockout. The green light reports high heat separately. Match manual W415-1241 revision B before using this chart.
Napoleon furnace error codes need the light’s colour as well as its flash count: on the 9600 B series, the red light gives the numbered faults, while the green light reports high heat. Napoleon’s manual gives each light its own chart.
This guide follows 9600 B series manual W415-1241, revision B, dated April 4, 2016. Match your furnace and its control instructions before using it. The broader furnace blinking light guide explains why a number from another brand’s chart is not enough.
Before you start
What to carry: a torch, your model information and a phone or pen. Record the light’s colour, whether it stays on or flashes, and the repeated count. Keep a note of whether the furnace never lit or stopped after heating.
Gas or electric? Napoleon identifies the 9600 B as a gas furnace. This chart is not for an electric air handler or an outdoor heat pump.
Keep the doors fitted. Read an indicator only where it is visible from outside the closed cabinet. Napoleon requires all doors and panels in place during normal operation. If you cannot see the light safely, leave access to the service person.
Renting? Send the model, pattern and heating symptoms to your property manager so they can arrange service.
Napoleon says that if you smell gas, do not light an appliance, touch electrical switches or use a phone inside. Leave immediately. Call the gas supplier at once from a neighbor’s phone and follow its instructions. If you cannot reach the supplier, call the fire department.
Its user instructions also say not to reenter until the gas supplier or fire department authorizes it.
If the furnace overheats or the gas burners fail to shut off, Napoleon requires the manual gas valve closed before electrical power is shut off. Approach a shutoff only if it is safe. Have the service person check the plastic vents and wires for damage before restarting.
Napoleon reserves installation and service for a qualified installer, service agency or gas supplier. Leave internal switches, live electrical tests and gas controls to them. Do not disable the blower door safety switch, which Napoleon expressly forbids.
Red and green are different readings
Identify the light before counting
Napoleon’s page 52 defines a steady red light as normal operation. A red light that is off means either no power to the control or a detected control hardware fault. Darkness alone does not establish which of those is present.
For the separate green AN2 light, Napoleon gives three states: off means no high heat demand, on means high heat is requested and operating normally, and flashing means high heat demand with the high pressure switch not closed.
A green light that is off therefore has a different meaning from a red light that is off. Write down which one you saw before choosing a row below.
The 9600 B red flash chart
These are the red AN1 definitions in section 19.4 of Napoleon’s revision B manual. They describe the control’s indication, not a confirmed failed part.
| Red indication | Meaning in this manual |
|---|---|
| Off | No power to the control, or a detected control hardware fault |
| Steady on | Normal operation |
| 1 flash | High limit switch open |
| 2 flashes | Pressure switch open while the inducer is on |
| 3 flashes | Pressure switch closed while the inducer is off |
| 4 flashes | Control in a one hour lockout |
| 5 flashes | L1 and neutral polarity problem |
| 6 flashes | Too many limit trips during one heat request |
| 7 flashes | Pressure switch cycle lockout |
| 8 flashes | Lockout after too many flame dropouts |
| 9 flashes | Not used |
| 10 flashes | Flame present with the gas valve off |
Pressure faults and limit trips
Keep two, three and seven red distinct
In Napoleon’s chart, two red flashes mean the pressure switch is open while the inducer is running. Three mean it is closed while the inducer is off. Seven is a pressure switch cycle lockout. Passing on the exact count preserves those differences.
Napoleon’s operating sequence explains one two-flash condition: if the low pressure switch has not closed within 60 seconds, the control displays two red flashes and stops the exhauster for 60 minutes. That timed response is not proof that the switch itself needs replacing.
For an observation you can make from outside, Napoleon says not to let snow, ice or debris accumulate around the outdoor exhaust and intake terminals. Report an obstruction you cannot reach safely. Leave pipe disassembly and switch tests for service.
The furnace pressure switch guide explains the air path in more detail.
Treat one and six red as limit reports
Napoleon defines one red flash as an open high limit and six as too many limit trips within one heat request. These are different reports; neither row identifies a replacement part by itself.
For routine care, Napoleon’s maintenance section says dirty filters raise operating temperatures. It calls for inspection and cleaning or replacement as necessary. This gives you a useful maintenance check without assuming a dirty filter explains every trip.
Outside the gas or overheating emergency above, disconnect electrical power before any filter maintenance, as Napoleon requires. Follow the instructions for your installed filter access. If you are unsure how it comes out, the user manual directs you to the installer or service technician.
Napoleon requires the filter refitted in its original airflow direction. Put the access doors and panels back before normal operation. If the limit indication continues, give the service person both the code and the maintenance you completed.
Lockout, polarity and an unexpected flame
Describe the difference between four and eight red
Napoleon’s diagnostic table labels four red flashes a one hour control lockout. Eight red flashes specifically identify lockout from too many flame dropouts.
For eight, section 17.3 describes up to five flame losses, with four recycles, during one heat request before lockout. It also specifies a one hour lockout for that condition. Tell the technician whether you had already noticed the furnace lighting and then losing its flame.
There is no need to open the cabinet or force another cycle to gather that information. A timed lockout describes the control’s response; it does not show that the cause has gone away. Avoid repeated power cycling to keep an unresolved fault running.
Leave five and ten red for qualified service
Napoleon identifies five red flashes as an L1 and neutral polarity problem. Leave supply wiring and polarity tests to the service person.
Ten red means flame is present with the gas valve off in this chart. Arrange qualified service before using the furnace again. If gas smell or overheating accompanies it, follow the emergency instructions above first.
What each one takes
| Finding | Work involved |
|---|---|
| Identify red or green | Record the light, state and full furnace model |
| Routine filter care | Safe electrical isolation, the installed filter’s procedure and secure reassembly |
| Pressure or limit indications | Service checks of the relevant circuit and operating conditions |
| Lockout or repeated flame loss | Diagnosis of the failed heating sequence before choosing parts |
| Polarity or unexpected flame | Qualified electrical or gas control investigation |
Questions people ask
Where is the Napoleon 9600 furnace error code PDF?
The 9600 B revision B manual has the red and green diagnostic charts on page 52, section 19.4. Check W415-1241 and the April 4, 2016 revision date against your instructions.
What do nine red flashes mean?
Napoleon marks nine flashes as not used in this chart. If you record that count, ask the technician to confirm the model, installed control and pattern rather than borrowing a meaning from another furnace.
Can the technician retrieve previous faults?
Yes. Napoleon’s section 19.5 says this control stores the last five faults and displays the newest first using its push button. Holding that button for more than five seconds clears history. Leave the internal button alone so service can retrieve the record.
Is the amber CFM light another fault code?
Napoleon’s page 48 describes an amber airflow indicator for models equipped with an ECM 2.3 or EON motor. Each flash represents 100 CFM on that indicator. Do not apply the red fault chart to it.
Can I use this list for a different Napoleon series?
This page verifies the 9600 B against W415-1241 revision B only. Use the instructions matching your series and installed control before applying a code meaning or restart procedure.
The other furnace guides: a furnace that will not ignite, limit switch trips and a furnace that is not heating.
Sources: Napoleon 9600 B Series Installation and Operating Instructions, W415-1241 / B / 04.04.16, cover, pages 46, 48, 50 and 52; included user's information pages 61, 63, 65 and 68.