State Water Heater Error Codes: B2-70, 111, ECC and More

State Water Heater Error Codes: B2-70, 111, ECC and More
Short answer

State's SUF Series 300 and 301 manual calls B2-70 an ignition failure. Its 140H to 540H tankless guide uses 111 for ignition failure, while the Premier hybrid guide calls ECC a compressor fault. Match the model and control before choosing a chart.

State water heater error codes need a model beside them. In State’s manuals, B2-70 on the SUF gas tank and 111 on the 140H to 540H tankless range both mean ignition failure. ECC belongs to a different chart: the Premier hybrid guide says its heat pump compressor is not functioning.

Find the matching section below before trying a reset. The charts cover specific State manuals and controls, rather than every heater with a State badge.

Before you start

What to carry: a torch, a pen and your heater’s paperwork. Copy the model, series, full code and any words on the screen.

Gas or electric? State’s SUF and 140H to 540H manuals here cover gas heaters. Its ESM control guide covers a residential electric tank, and the Premier hybrid guide covers an electric tank with a heat pump.

Renting? Send that information to the person responsible for repairs before arranging work on the heater.

A fault code does not make a reset safe.
For a gas smell, State says not to light an appliance, touch electrical switches or use a phone inside. Leave and call the gas supplier from outside, and follow their instructions. If the supplier cannot be reached, call the fire department.

If a carbon monoxide alarm sounds, CPSC says to get outside without searching for the source, call emergency services and count everyone to check that nobody is missing. Wait for permission to return. If an appliance caused the alarm, CPSC says not to use it until trained personnel have serviced it.

If the alarm sounds again within 24 hours of being allowed back, CPSC says to repeat those emergency steps and call a qualified appliance technician to check all fuel burning equipment.

For an overheating SUF tank, or gas that fails to shut off, State says to close the main gas shutoff valve. Arrange qualified service. State also says not to operate this SUF after flooding, water damage, external damage, firing without water or sooting until a qualified technician has corrected the problem. For an ESM electric tank showing E02, State’s first step is electrical power off at the breaker because the water exceeded its high limit.

State requires power disconnected before electrical service. Its SUF manual warns against bypassing control circuits or components. Leave wiring, burner parts, safety switches and control boards to a qualified person. Do not remove the plastic wiring guard on the electric tank.

Choose the chart from the heater and its control

Check 1No parts needed to identify the control

Keep the full fault with the model

Use the label or paperwork without opening an electrical compartment. Include the characters after a hyphen, and say whether the display belongs to the heater or a separate controller.

For the SUF 60120 through SUF 100250, Series 300 and 301, State distinguishes a fault marked with an exclamation mark from an alert marked with a question mark. A fault stops heating; an alert allows operation but still needs service as soon as possible.

If your heater’s label or display does not match a section here, use its own manual. State’s hybrid guide asks callers to have the model and serial number ready.

STATE: START WITH THE MATCHING FAMILYASUF 300 / 301B2-70Ignition failureSUF 60120 to 100250B140H to 540H111Ignition failureGas tankless guideCPremier hybridECCCompressor faultGuide 100323093State manual examples. Keep the full model, series and screen message together.
Three State displays with different manuals behind them. These examples do not form one interchangeable code list.

B2-70 on a SUF gas tank

Check 2Ignition and gas pressure testing need a service visit

Read the message beside the number

State’s SUF Series 300 and 301 manual shows B2-70, Ignition Failure: the control has not detected flame. Its checks include gas pressure, flame sensing, spark ignition, connections and grounding. That list calls for diagnosis, rather than buying a flame rod from the code alone.

Here are other messages in that manual for SUF 60120 through SUF 100250:

Code State’s displayed message What to tell the service agent
A6-501 Low Gas Pressure Report any known interruption to the gas supply
A7-1201 Blocked Air Intake Report visible obstruction or damage at the outdoor intake
A5-401 High Temp Limit Exceeded The energy cut off has stopped the heater; report unexpectedly hot water
D6-8 No Water The powered anode has not detected water; report recent draining or plumbing work

Reset after the cause is corrected. State specifies power off at the breaker for approximately 20 seconds, then back on, for this SUF control. The same section says a fault requires qualified service before operation is restored. An uncorrected fault locks out again.

An A.O. Smith Vertex with worded messages has its own Vertex fault guide. Use that page for the named Vertex models, rather than borrowing their temperature limits for a State SUF.

111 on a State tankless heater

Check 3Supply observations first; internal tests need a technician

Separate failed ignition from a lost flame

In State’s 140H, 240H, 340H and 540H guide, 111 means ignition failure and 121 means loss of flame. Its no hot water checks include the controller being on, gas and water supply being available, and enough water flowing through the heater.

Tell the technician whether it never lights or lights before the water turns cold. State’s fault chart then points to internal checks such as the high limit switch, wiring, flame rod and ignition components.

Code State’s meaning for this tankless family
291 Blocked condensate drain system
311 Outlet temperature sensor fault on 140H, 240H and 340H; heat exchanger temperature sensor fault on 540H
321 Inlet temperature sensor fault
331 Outlet temperature sensor fault on 540H only
611 Fan motor fault
991 Imperfect combustion

State marks 111 and 121 among the codes that clear when water flow stops. The code disappearing after you close a tap does not mean the fault is fixed.

E01 to E71 on the ESM electric control

Check 4Electrical faults need a qualified person and testing equipment

Match the Energy Saver Module display

Use this chart only for the Energy Saver Module, or ESM, and Electronic Thermostat, or ET, described in State’s residential electric guide 100264219. It is separate from the hybrid chart below.

ESM code What State’s diagnostic chart identifies
E01 Dry firing: electrical power on before the tank is completely full
E02 Water temperature above the high limit
E03 / E07 Upper / lower temperature sensor failure
E04 / E05 Upper / lower element circuit failure
E06 Electronic thermostat internal processor failure
E08 Energy Saver Module failure
E09 to E12 Electronic thermostat error
E51 / E52 No communication with the thermostat / wrong data received from it
E71 Energy Saver Module temperature sensor failure

For E01, State says to turn off electrical power at the breaker and fill the tank before restoring power. If this followed installation or draining, contact the installer to complete those steps.

State labels the chart’s repair instructions as guidance for a qualified person. A thermostat error is not an instruction to remove the cover and move wires.

ECC and the Premier hybrid display

Check 5Filter cleaning uses household tools; compressor faults need service

Separate compressor trouble from filter care

State links hybrid guide 100323093 to its HPX-66-DHPTCTA 130. Use this section for a Premier hybrid supplied with that guide. For ECC, it says the heat pump compressor is not functioning and directs the owner to technical assistance.

The same State chart separates ECF, frequent compressor starting and stopping, from ECC. ECF leads to filter and installation space checks; a compressor running without its fan needs technical support. SF is the dirty filter message.

For SF, State’s maintenance steps are: switch power off at the breaker, slide out the filter using its two tabs, vacuum away debris, and put the cleaned or replacement filter back. Restore power after refitting it.

STATE HYBRID: SF FILTER CARESFBFilter position is a schematic.AIsolate the powerSwitch off at the breakerbefore touching the filter.BRemove and cleanSlide out using the tabs.Vacuum dust and debris.CRefit, then restorePut the filter back first.Then restore power.
Filter care for State hybrids using guide 100323093. Isolate electrical power before sliding out the filter, then refit it before restoring power.

State lists EoF as a condensate management problem. Its checks include drainage, the heater being level and an accessory condensate pump, if fitted. Report water around the heater or an unpowered pump; leave work inside the top cover to service.

For an A.O. Smith hybrid, use the separate A.O. Smith hybrid code guide.

What each one takes

Situation What the job involves
Unidentified display The label, full message and matching manual
SUF B2-70 or tankless 111 A qualified gas service agent to test the ignition system
ESM sensor, element or communication fault Electrical diagnosis before choosing a replacement part
Hybrid SF Power isolated, filter cleaned or replaced
Hybrid ECC Technical support and compressor diagnosis

Questions people ask

What does State code BE-1 mean?

Keep the words beside BE-1 when requesting service. The SUF owner chart above does not list that exact code. State’s separate commercial service table lists 0BE as no blower speed feedback, but that alone does not verify BE-1 for your model or series.

What about 1B0-0?

State’s commercial electric service handbook 100319205 lists 1B0 under internal control hardware failures. That handbook covers its stated 52, 80 and 120 gallon commercial models. It does not establish the meaning of the extra -0 for every State heater; have the full code matched before replacing a board.

Are dashes, ICE and HPO hybrid faults?

State’s hybrid guide 100323093 lists these as normal operation: a system diagnostic, defrost, or conditions outside the heat pump’s operating range. HPO includes air below 45 degrees F or above 120 degrees F, or average tank water at 59 degrees F or less.

Can I silence the hybrid alarm?

For alarms accompanying the codes marked in guide 100323093, State says pressing any button on the display cancels the sound. Record the code first so you can still explain the problem.

Is there a State error codes PDF?

Yes. The State PDF links in the gas, tankless, electric and hybrid sections above open the manuals used here.

For symptoms without a code, start with a water heater with no hot water. For A.O. Smith heaters, see Vertex messages or hybrid display codes.

Sources: State SUF 60120 through SUF 100250 Series 300/301 Instruction Manual 100303964 Rev. D, pp. 1, 60 to 63; State 140H/240H/340H/540H Installation Manual and Owner's Guide, pp. 1, 57, 60 to 61; State Residential Electric Use and Care Guide 100264219, pp. 20 to 22; State Hybrid Electric Use and Care Guide 100323093, pp. 1, 20 to 21, 30; State HPX-66-DHPTCTA 130 product page linking manual 100323093; State Commercial Electric Service Handbook 100319205 Rev. B, pp. 1, 3, 74, 76; CPSC Carbon Monoxide Questions and Answers.