State's SUF Series 300 and 301 manual calls B2-70 an ignition failure. Its 140H to 540H tankless guide uses 111 for ignition failure, while the Premier hybrid guide calls ECC a compressor fault. Match the model and control before choosing a chart.
State water heater error codes need a model beside them. In State’s manuals, B2-70 on the SUF gas tank and 111 on the 140H to 540H tankless range both mean ignition failure. ECC belongs to a different chart: the Premier hybrid guide says its heat pump compressor is not functioning.
Find the matching section below before trying a reset. The charts cover specific State manuals and controls, rather than every heater with a State badge.
Before you start
What to carry: a torch, a pen and your heater’s paperwork. Copy the model, series, full code and any words on the screen.
Gas or electric? State’s SUF and 140H to 540H manuals here cover gas heaters. Its ESM control guide covers a residential electric tank, and the Premier hybrid guide covers an electric tank with a heat pump.
Renting? Send that information to the person responsible for repairs before arranging work on the heater.
For a gas smell, State says not to light an appliance, touch electrical switches or use a phone inside. Leave and call the gas supplier from outside, and follow their instructions. If the supplier cannot be reached, call the fire department.
If a carbon monoxide alarm sounds, CPSC says to get outside without searching for the source, call emergency services and count everyone to check that nobody is missing. Wait for permission to return. If an appliance caused the alarm, CPSC says not to use it until trained personnel have serviced it.
If the alarm sounds again within 24 hours of being allowed back, CPSC says to repeat those emergency steps and call a qualified appliance technician to check all fuel burning equipment.
For an overheating SUF tank, or gas that fails to shut off, State says to close the main gas shutoff valve. Arrange qualified service. State also says not to operate this SUF after flooding, water damage, external damage, firing without water or sooting until a qualified technician has corrected the problem. For an ESM electric tank showing E02, State’s first step is electrical power off at the breaker because the water exceeded its high limit.
State requires power disconnected before electrical service. Its SUF manual warns against bypassing control circuits or components. Leave wiring, burner parts, safety switches and control boards to a qualified person. Do not remove the plastic wiring guard on the electric tank.
Choose the chart from the heater and its control
Keep the full fault with the model
Use the label or paperwork without opening an electrical compartment. Include the characters after a hyphen, and say whether the display belongs to the heater or a separate controller.
For the SUF 60120 through SUF 100250, Series 300 and 301, State distinguishes a fault marked with an exclamation mark from an alert marked with a question mark. A fault stops heating; an alert allows operation but still needs service as soon as possible.
If your heater’s label or display does not match a section here, use its own manual. State’s hybrid guide asks callers to have the model and serial number ready.
B2-70 on a SUF gas tank
Read the message beside the number
State’s SUF Series 300 and 301 manual shows B2-70, Ignition Failure: the control has not detected flame. Its checks include gas pressure, flame sensing, spark ignition, connections and grounding. That list calls for diagnosis, rather than buying a flame rod from the code alone.
Here are other messages in that manual for SUF 60120 through SUF 100250:
| Code | State’s displayed message | What to tell the service agent |
|---|---|---|
| A6-501 | Low Gas Pressure | Report any known interruption to the gas supply |
| A7-1201 | Blocked Air Intake | Report visible obstruction or damage at the outdoor intake |
| A5-401 | High Temp Limit Exceeded | The energy cut off has stopped the heater; report unexpectedly hot water |
| D6-8 | No Water | The powered anode has not detected water; report recent draining or plumbing work |
Reset after the cause is corrected. State specifies power off at the breaker for approximately 20 seconds, then back on, for this SUF control. The same section says a fault requires qualified service before operation is restored. An uncorrected fault locks out again.
An A.O. Smith Vertex with worded messages has its own Vertex fault guide. Use that page for the named Vertex models, rather than borrowing their temperature limits for a State SUF.
111 on a State tankless heater
Separate failed ignition from a lost flame
In State’s 140H, 240H, 340H and 540H guide, 111 means ignition failure and 121 means loss of flame. Its no hot water checks include the controller being on, gas and water supply being available, and enough water flowing through the heater.
Tell the technician whether it never lights or lights before the water turns cold. State’s fault chart then points to internal checks such as the high limit switch, wiring, flame rod and ignition components.
| Code | State’s meaning for this tankless family |
|---|---|
| 291 | Blocked condensate drain system |
| 311 | Outlet temperature sensor fault on 140H, 240H and 340H; heat exchanger temperature sensor fault on 540H |
| 321 | Inlet temperature sensor fault |
| 331 | Outlet temperature sensor fault on 540H only |
| 611 | Fan motor fault |
| 991 | Imperfect combustion |
State marks 111 and 121 among the codes that clear when water flow stops. The code disappearing after you close a tap does not mean the fault is fixed.
E01 to E71 on the ESM electric control
Match the Energy Saver Module display
Use this chart only for the Energy Saver Module, or ESM, and Electronic Thermostat, or ET, described in State’s residential electric guide 100264219. It is separate from the hybrid chart below.
| ESM code | What State’s diagnostic chart identifies |
|---|---|
| E01 | Dry firing: electrical power on before the tank is completely full |
| E02 | Water temperature above the high limit |
| E03 / E07 | Upper / lower temperature sensor failure |
| E04 / E05 | Upper / lower element circuit failure |
| E06 | Electronic thermostat internal processor failure |
| E08 | Energy Saver Module failure |
| E09 to E12 | Electronic thermostat error |
| E51 / E52 | No communication with the thermostat / wrong data received from it |
| E71 | Energy Saver Module temperature sensor failure |
For E01, State says to turn off electrical power at the breaker and fill the tank before restoring power. If this followed installation or draining, contact the installer to complete those steps.
State labels the chart’s repair instructions as guidance for a qualified person. A thermostat error is not an instruction to remove the cover and move wires.
ECC and the Premier hybrid display
Separate compressor trouble from filter care
State links hybrid guide 100323093 to its HPX-66-DHPTCTA 130. Use this section for a Premier hybrid supplied with that guide. For ECC, it says the heat pump compressor is not functioning and directs the owner to technical assistance.
The same State chart separates ECF, frequent compressor starting and stopping, from ECC. ECF leads to filter and installation space checks; a compressor running without its fan needs technical support. SF is the dirty filter message.
For SF, State’s maintenance steps are: switch power off at the breaker, slide out the filter using its two tabs, vacuum away debris, and put the cleaned or replacement filter back. Restore power after refitting it.
State lists EoF as a condensate management problem. Its checks include drainage, the heater being level and an accessory condensate pump, if fitted. Report water around the heater or an unpowered pump; leave work inside the top cover to service.
For an A.O. Smith hybrid, use the separate A.O. Smith hybrid code guide.
What each one takes
| Situation | What the job involves |
|---|---|
| Unidentified display | The label, full message and matching manual |
| SUF B2-70 or tankless 111 | A qualified gas service agent to test the ignition system |
| ESM sensor, element or communication fault | Electrical diagnosis before choosing a replacement part |
| Hybrid SF | Power isolated, filter cleaned or replaced |
| Hybrid ECC | Technical support and compressor diagnosis |
Questions people ask
What does State code BE-1 mean?
Keep the words beside BE-1 when requesting service. The SUF owner chart above does not list that exact code. State’s separate commercial service table lists 0BE as no blower speed feedback, but that alone does not verify BE-1 for your model or series.
What about 1B0-0?
State’s commercial electric service handbook 100319205 lists 1B0 under internal control hardware failures. That handbook covers its stated 52, 80 and 120 gallon commercial models. It does not establish the meaning of the extra -0 for every State heater; have the full code matched before replacing a board.
Are dashes, ICE and HPO hybrid faults?
State’s hybrid guide 100323093 lists these as normal operation: a system diagnostic, defrost, or conditions outside the heat pump’s operating range. HPO includes air below 45 degrees F or above 120 degrees F, or average tank water at 59 degrees F or less.
Can I silence the hybrid alarm?
For alarms accompanying the codes marked in guide 100323093, State says pressing any button on the display cancels the sound. Record the code first so you can still explain the problem.
Is there a State error codes PDF?
Yes. The State PDF links in the gas, tankless, electric and hybrid sections above open the manuals used here.
For symptoms without a code, start with a water heater with no hot water. For A.O. Smith heaters, see Vertex messages or hybrid display codes.
Sources: State SUF 60120 through SUF 100250 Series 300/301 Instruction Manual 100303964 Rev. D, pp. 1, 60 to 63; State 140H/240H/340H/540H Installation Manual and Owner's Guide, pp. 1, 57, 60 to 61; State Residential Electric Use and Care Guide 100264219, pp. 20 to 22; State Hybrid Electric Use and Care Guide 100323093, pp. 1, 20 to 21, 30; State HPX-66-DHPTCTA 130 product page linking manual 100323093; State Commercial Electric Service Handbook 100319205 Rev. B, pp. 1, 3, 74, 76; CPSC Carbon Monoxide Questions and Answers.