Home / Water heaters / GE GeoSpring Water Heater Error Codes: F2 to F23

GE GeoSpring Water Heater Error Codes: F2 to F23

Ray BennettBy Ray Bennett · Updated 2 October 2026 · 6 min read · Checked against the maker’s manual
GE GeoSpring Water Heater Error Codes: F2 to F23
Short answer

On a GE GeoSpring hybrid water heater, F11 means it was powered before the tank was full, bAd linE is the wrong voltage, F14 or the filter light is a dirty air filter and F20 a clogged condensate drain, and those are yours to fix. F2 to F10 and the letter codes F-C to F-L need service. The newer GE Profile GEOSPRING uses F61 to F96.

The GeoSpring is GE’s hybrid water heater: a heat pump on top of an electric tank, with two heating elements as backup. When it finds a fault, it beeps and shows a code. For many faults, GE says it may switch itself to another heating mode, so you still have hot water while it costs more to run.

Everything on this page comes from GE’s owner’s manual 49-50300-2 for the GEH50 and GEH80 GeoSpring models, and GE’s support page for the newer GE Profile GEOSPRING. GE made the GeoSpring from 2012 to December 2016, and GE says Bradford White now handles its service and support.

Before you start

What to carry: a torch, and a vacuum or a damp cloth for the air filter. Twenty minutes.

Gas or electric? Electric, on a 240 volt circuit, with a heat pump and two elements.

Wake the display. GE says the display goes blank after 30 seconds. Press any button to wake it.

Quiet the beeping. For a service code, GE says press the UP or DOWN arrow, and give the code on the display to whoever comes to fix it.

A flashing green light is normal. In Hybrid and High Demand/Boost modes, GE says the Electric/Standard light flashes whenever the elements are heating.

What GE says to leave alone. There is no power button. GE says the power can only be shut off at the breaker or the disconnect switch. Switch it off there before any work inside the covers.

Never power it empty. GE says the elements are damaged if they run without water, and the warranty does not cover damage from an empty or part empty tank.

The TCO. The heater has a manual reset limit that cuts the elements if the water gets far too hot. GE says a qualified technician should reset it and find out why it tripped.

The codes you can clear yourself

THE GEOSPRING CODES YOU CAN CLEAR F11 dry tank: fill it, then switch the power off and on bAd linE not 240 volts: the installer checks the wiring F14 or the filter light dirty air filter: clean it, then hold FILTER F20 condensate drain clogged: clear the lines F16 anode rod near its end: replace it soon Green light flashing the elements are heating: normal, not a fault The letter codes F-C to F-L and F2 to F10 are a service call.
The GeoSpring codes with an owner fix. The letter codes and F2 to F10 are a service call.
Check 1Free, twenty minutes

Work the owner codes

F11: dry tank. The heater was powered before the tank was full. Fill it completely, press ENTER to stop the alarm, then switch the power off and on. GE adds that on a tank you know is full, F11 can be a false alarm at start up. Turn the breaker off for about 10 minutes, then back on.

bAd linE, also F12. The heater is not getting the 240 volts it needs. GE says switch it off and have the installer check the wiring. Some utility switches drop the supply to 120 volts at peak times, and GE says those must come off the heater’s circuit.

F14 or the red filter light. The air filter is dirty. The next section shows how to clean it.

F20: the condensate drain. It is clogged and the heat pump has stopped. Press any button to silence it, then take off the drain lines and clear the debris. GE says the elements keep making hot water until the drain runs again.

F16: the anode rod. On some models, it means the rod is near the end of its life. Press ANODE once to silence it, and replace the rod soon: what an anode rod does.

Cleaning the air filter

Check 2Free, ten minutes

Clean it the way GE says

Leave the power on. GE says to leave it on. Squeeze the two tabs on top of the heater and lift the filter out.

Clean it. Vacuum it, wipe it with a damp cloth or rinse it in warm water. Let it dry, then push it back into its slots.

Reset the alarm. Press and hold FILTER. GE says the heater goes back to the mode it was in before.

If it comes back within days. GE says a filter alarm that returns within a few days of cleaning may be a refrigerant leak, which needs a technician.

Why it matters. GE says a filter that gets too dirty switches the heater to Electric/Standard mode, and the energy savings are lost.

Not enough hot water, or a cold room

GIVE THE HEAT PUMP ITS AIR 8 in clear GeoSpring air filter 7 in The room at least 700 cubic feet, 10 by 10 by 7 feet smaller than that: louvered doors or similar ventilation The heat pump cools the room it stands in, and GE calls that normal.
GE's space rules: 7 inches from the wall, 8 inches clear above the filter, and a room of at least 700 cubic feet or louvered doors.
Check 3Free, ten minutes

Give it air and the right mode

Space around it. GE says the heater should stand 7 inches from the wall with 8 inches clear above the air filter.

Room size. A room smaller than 700 cubic feet, 10 by 10 by 7 feet, needs louvered doors or similar ventilation. The heat pump takes heat from the room air, so a small room gets cooler, and a cooler room slows the heating.

The mode. Heat Pump is the cheapest mode to run and the slowest. Hybrid is the factory setting. High Demand/Boost brings the elements in sooner, and GE suggests it for a household that uses more hot water than average.

Winter. GE says colder water coming in takes longer to heat, which is normal. It suggests raising the set temperature: why a shower runs out of hot water.

The room feels colder. GE says that is normal. The heat in the water comes from the air around it.

Codes that need a technician

Code What GE calls it
F-C Evaporator not frost free, probable refrigerant leak
F-D Superheat too low, possible refrigerant leak
F-E Discharge temperature above limit, possible refrigerant leak
F-F Electronic expansion valve out of range, probable refrigerant leak
F-G Ambient temperature check, data for the technician
F-I Refrigerant leak test, probable refrigerant leak
F-J Concurrent load high current
F-L Evaporator not defrosting
F2 Tank temperature sensor
F3 Compressor
F4 Fan
F5, F6 Evaporator inlet or outlet temperature sensor
F7 Compressor outlet sensor
F8 Ambient temperature sensor
F9, F10 Lower or upper heating element
F13 Stuck key
F15 DataFlash fault
F17 Empty tank, or the anode rod wired wrongly
F18 Current transformer wired wrongly
F19 Low line voltage, data for the technician
F21, F22 Software or settings update failure
F23 Micro A/D failure
Check 4A service call

Hand over the code

Hot water meanwhile. GE says the heater may switch itself to another heating mode so hot water keeps coming.

F17. Check the tank is completely full first. If it is and F17 stays, GE says to contact service.

F9 or F10. One element has failed, and GE sends it to service. Here is how an element is tested: how to test a water heater element.

The newer GE Profile GEOSPRING

GE’s support page lists the codes on the current GE Profile GEOSPRING, from June 2025 on, that an owner can often clear.

Code What GE says What to do
F61 Tank water too hot Should correct itself
F62 Incoming water too hot Reduce any preheating, or call service
F73 Condensate drain pan port clogged Clear the drain
F74 Filter dirty Clean it; if it repeats, probable refrigerant leak
F75 Dry tank Make sure there is water in the tank
F78 Leak sensor found water Find the leak; reset the shut off valve if fitted
F81 Leak sensor battery low Replace the battery
F96 CTA module disconnected or battery low Reconnect it or replace the battery

Questions people ask

What does F11 mean on a GeoSpring?

A dry tank: it was powered before it was full. Fill it, press ENTER, and switch the power off and on. If the tank was already full, turn the breaker off for about 10 minutes first.

What does bAd linE mean?

The heater is not getting the right voltage, usually because of the wiring. Switch it off and have the installer check it.

Why is the filter light on?

The air filter on top needs cleaning. Clean it, put it back and hold FILTER to reset it. If it comes back within days, GE says it may be a refrigerant leak.

Why is the green light flashing?

In Hybrid and High Demand/Boost modes, GE says the Electric/Standard light flashes whenever the elements are heating. It is normal.

What does F20 mean on a GeoSpring?

The condensate drain is clogged. Clear the drain lines and the heater goes back to using the heat pump once it drains.

Who services a GeoSpring now?

GE says Bradford White handles service and support for the GeoSpring models made from 2012 to 2016.

Sources: GE Appliances owner's manual 49-50300-2 for the GeoSpring hybrid electric water heaters GEH50DEEJS, GEH50DFEJS, GEH80DEEJS and GEH80DFEJS, and GE Appliances' support article on GE Profile GEOSPRING fault codes