On a single pole baseboard thermostat, Dimplex says there is no off position and power is continuous to the heater, and Qmark says it can still heat when the room is colder than its lowest setting. Check the thermostat is in the heater's room, out of drafts. Cadet and Stelpro also list a faulty thermostat and a heater too small for the room. Glowing red: breaker off.
In the makers’ charts, an electric baseboard heater that will not stop heating points first at the thermostat. Cadet’s chart and Stelpro’s ABA baseboard chart also list a heater too small for the room, and Cadet adds a heater with no thermostat at all.
Most of the checks need only your eyes and the thermostat. The wiring and a new thermostat are an electrician’s job.
Before you start
What to carry: a torch, and your phone to photograph the label on the heater and the thermostat.
Gas, oil or electric? This page is about electric baseboard heaters: a long metal box along the wall with no pipes, wired straight into the house. If your baseboard has water pipes and runs off a gas or oil boiler, it is hot water baseboard, which this page does not cover; the hot water guide is a hot water radiator or baseboard not heating.
Know your thermostat. Cadet says the thermostat is either on the wall or on the heater. Dimplex says a single pole thermostat has only a low setting with no off position, and a double pole thermostat has an off position.
Keep it clear. Cadet says the heater is hot when in use, to keep furniture, pillows, bedding, papers, clothes and curtains away from it, and that to prevent a possible fire, nothing may block it.
Breaker off before any work. Cadet says to turn the power off at the main disconnect panel before any work on a heater, and Stelpro says there is still current in its ABA heater with the thermostat set to off. Dimplex says heaters and their controls should be installed by a licensed electrician.
Why it keeps running
Turn it all the way down, and wait
The test. Cadet’s instructions for a mechanical thermostat are to turn the knob all the way to the right, then, once the room is comfortable, turn it to the left just until it clicks and the heater turns off. King and Qmark give a check for a newly installed system: with every thermostat at LOW or NO HEAT, wait 3 to 5 minutes, and none of the heaters should be running.
No off position. Dimplex says a single pole thermostat breaks only one side of the power line, so power is continuous to the heater, and its knob has a low setting but no off. Marley’s Qmark thermostat notes say single line break thermostats have no OFF position and will operate at a temperature below their minimum set point.
So to stop it. On a single pole thermostat, a room colder than the lowest setting can still turn the heater on. To cut the power fully, turn off its breaker. Dimplex says a double pole thermostat breaks both sides of the line, so its off position cuts all power to the heater.
Heating a warm room at the lowest setting. That is not the single pole design at work. Cadet lists a defective thermostat for a heater that does not turn off, and King and Qmark say that if a heater runs with its thermostat at LOW or NO HEAT after installation, disconnect the power and check the wiring. Turn its breaker off and call an electrician.
Check where the thermostat is
The same room. Cadet’s instructions for wiring several heaters to one thermostat say the thermostat and the heaters must be in the same room. Qmark recommends no more than one thermostat in each room, and says not to keep different rooms at different temperatures unless the doors are kept closed; with the rooms open, all the thermostats should have the same setting.
Drafts and heat. Honeywell says its RLV4300 digital thermostat shows the wrong temperature if it is in a draft, if the sticker on its screen has not been peeled off, or if it is near or above a heat source such as a light dimmer. Its installation instructions put it about 5 feet high on an inside wall facing the heater, away from drafts such as the top of a staircase or an air outlet, dead air spots such as behind a door, and direct sunlight.
King’s chart. King says sunlight or other heat sources can throw a thermostat off, and to move the thermostat or remove the heat source. It also lists improper calibration, fixed with the calibration screw under the thermostat’s cover.
Moving or adjusting one. A line voltage thermostat is wired to the heater circuit, so moving it or opening its cover is a job for an electrician.
A digital thermostat: check the schedule
The installation check. Honeywell’s check after installing its RLV4300 is that the heat turns on when you raise the setpoint with the Up button, and off when you lower it with the Down button.
A change that does not stick. In Automatic mode, Honeywell says a setpoint changed with the Up or Down button is used only until the end of the current period, and Manual mode is the permanent override of the schedule. Its default schedule asks for 70°F at 6:00 every day and again at 18:00 on weekdays.
Heating before you expect it. Honeywell says that with Early Start on, in Automatic mode, the thermostat starts heating early so the room is warm at the start of periods 1 and 3.
The wrong times. If the temperature does not follow the schedule, Honeywell says to make sure the thermostat is in Automatic mode, and to check the clock and the schedule: on the 12-hour format, PM must show on the screen for afternoon times. It says the time shows wrong if it was never set or the thermostat was without power for more than 5 hours.
Is the heater big enough for the room?
Too small. Cadet lists the wrong heater wattage for the room size as a cause of a heater that does not turn off, and its fix is a higher wattage model or more heaters, if the circuit allows. Stelpro’s ABA guide says a heater too small for the room runs continuously, and may fail sooner and turn yellow.
A rough size. Dimplex’s general rule is 10 watts of heat per square foot: a 1,000 watt heater heats 100 square feet in a standard insulated room. Stelpro gives the same 10 watts per square foot, based on a standard 8 foot ceiling, and says insulation and windows change what a room needs.
Getting it right. Stelpro says a specialist can work out a room’s heat losses, and to heat a large room it recommends several heaters instead of one, for example two 1,000 watt heaters instead of one 2,000 watt heater.
Adding a heater. Cadet says the load on one breaker is limited to 80 percent of the breaker’s capacity or the thermostat’s maximum rating, whichever is lower. Adding a heater is a job for an electrician.
A faulty thermostat, or none at all
A thermostat that has failed. Cadet’s fix for a defective thermostat is to replace it, and Stelpro’s ABA chart lists a defective thermostat or a wrong setting for a heater that runs continuously. King says a room that swings from too hot to too cold points to a defective or low quality thermostat, and that an electronic thermostat is the best.
No thermostat. Cadet says a thermostat is required for every heater, built into the heater or on the wall. King says its K Series heater does not come with a thermostat, and that baseboard heaters must be thermostatically controlled for efficient, safe operation.
A wiring fault. King and Qmark say that if any heater runs with its thermostat at LOW or NO HEAT after installation, disconnect the power and check the wiring. Turn its breaker off and call an electrician.
When it is also too hot
Overheating. Stelpro’s ABA chart lists a defective thermostat or a wrong setting for a heater that overheats, and Cadet says a heater on a higher voltage than its label will be destroyed and could start a fire. If it glows red, or keeps getting unusually hot and shutting off, turn its breaker off and leave it off until an electrician has looked at it.
A heater that keeps shutting itself off. Cadet says its baseboard heaters have a high-temperature safety shutoff that stops the power if the heater gets too hot inside and resets after cooling, and not to tamper with it. King says that if its safety limit keeps cycling the heater off and nothing is blocking it, disconnect the power and have a qualified electrician check and repair it.
Clearances. The makers’ distances for furniture and curtains are in a baseboard heater not working or not getting hot.
What each one costs
| The step | Cost |
|---|---|
| Turning it down, using the breaker for a full off | Nothing |
| Fixing a digital thermostat’s schedule or clock | Nothing |
| Moving a thermostat, or a new one | An electrician, plus the thermostat if it is a new one |
| A bigger heater, or another one | The heater and an electrician |
| A wiring fault | An electrician |
Questions people ask
Why won’t my baseboard heater turn off?
Cadet’s chart lists a defective thermostat, no thermostat at all, and a heater too small for the room. Stelpro’s ABA chart adds a wrong thermostat setting. A single pole thermostat has no off position, so the heater can still come on when the room is colder than the lowest setting.
Why is my baseboard heater on when the thermostat is turned all the way down?
Dimplex says a single pole thermostat keeps one side of the power line connected and has no off position, and Qmark says it will operate when the room is below its minimum set point. If it keeps heating a warm room at the lowest setting, Cadet lists a defective thermostat: turn the breaker off and call an electrician.
How do I turn a baseboard heater off completely?
With a double pole thermostat, turn it to OFF: Dimplex says that cuts all power. With a single pole thermostat, turn off the heater’s breaker. Before cleaning or any work, turn the breaker off either way, as Cadet says.
Why does my baseboard heater come on by itself?
A single pole thermostat can still heat when the room is colder than its lowest setting, Qmark says. Honeywell says its RLV4300 shows the wrong temperature in a draft. In Automatic mode with Early Start on, it starts heating early for periods 1 and 3, and a change made with Up or Down lasts only until the period ends.
Is it dangerous if a baseboard heater will not turn off?
It is hot whenever it runs, so keep furniture, bedding and curtains away, as Cadet says. If it glows red or keeps getting unusually hot and shutting off, Cadet says to turn its breaker off immediately.
The other electric heat guides: an electric baseboard heater not working, a baseboard heater making noise, an electric heater that smells like burning and a wall heater making noise.
Sources: Cadet electric baseboard heater owner's guide 720001, Dimplex electric heater technical support page and T Series owner's guide, Stelpro ABA baseboard user's guide, King Electrical K Series baseboard installation and troubleshooting chart, Marley Qmark TA line voltage thermostat instructions, and Honeywell Home RLV4300 line voltage thermostat owner's manual 33-00150
By 