Electric Wall Heater Not Working? Reset, Clean or Replace

Ray BennettBy Ray Bennett · Updated 2 October 2026 · 11 min read · Checked against the sources at the end
Electric Wall Heater Not Working? Reset, Clean or Replace
Short answer

An in-wall electric heater that stops may have tripped its overheat safety. Turn its breaker off, wait the time your maker gives (20 minutes on a Cadet Com-Pak, 15 on a King), clear and clean it, then turn it back on. Cadet says one that trips more than once a day must be replaced. Old Cadet and Encore models FW to ZC, and some Cadet Apex72 heaters, are recalled.

An electric wall heater is a fan, a heating element and a safety switch in a can in the wall. When one stops, one cause the makers list is that safety switch: something made it too hot and it shut the heater off.

Every maker resets it differently, so the steps below follow the manuals by name. First, check the heater is not one of the recalled ones.

Before you start

What to carry: a torch, a screwdriver for the grill screws, a hair dryer or a vacuum that can blow, and a soft brush. Half an hour, most of it waiting for the heater to cool.

Gas or electric? This page is about electric wall heaters, the fan heaters set into a wall with a grill and no flue or gas pipe. A gas wall furnace has a pilot and a vent: gas wall heater not working.

Find the model. CPSC says the brand and model on the older recalled Cadet and Encore in-wall heaters are on a label on the front of the heat box, behind the grill. Turn the power off at the breaker before you take the grill off: CPSC warns you risk electrocution and shock if you do not. Cadet warns breakers are often not marked correctly, so make sure the heater is really off before you reach in. On a Cadet Apex72, CPSC says the model and manufacturing date are on a rating label you can see through the bottom of the air outlet grill.

Check for a recall first. Old Cadet and Encore in-wall heaters. In 2000 CPSC announced a recall of more than 1.9 million Cadet and Encore models FW, FX, LX, TK, ZA, Z, RA, RK, RLX, RX, RW and ZC, sold mainly in California, Idaho, Montana, Oregon and Washington. CPSC says flames, sparks or molten particles can come out through the grill, that even heaters whose switches were repaired need to be replaced, and that they stay a fire hazard until they are. Sign-up for this recall closed in 2002, and CPSC’s notice now lists no remedy.

Cadet Apex72 high wall heaters. In 2024 Glen Dimplex Americas recalled Cadet Apex72 models HW128, HW132 and HW151 made March 1, 2021 through February 29, 2024, and HW162, HW162BP5, HW168 and HW168BP5 made before March 1, 2024, because the fan can fail and the heater can overheat and ignite. CPSC says to stop using them at once and contact Glen Dimplex for a free replacement.

Smoke, sparks or a burning smell. Turn the heater’s breaker off, and if there are flames, get everyone out and call 911. Cadet says not to reset the breaker until loose or shorted wiring has been found and repaired, and Cadet and King say never to use a heater after it malfunctions until a qualified electrician has inspected it.

The overheat reset, maker by maker

HOW EACH MAKER'S OVERHEAT RESET WORKS Cadet Com-Pak and Com-Pak Twin Thermostat below room temperature, or breaker off. Wait at least 20 minutes, clear the cause, back on. Cadet Energy Plus Breaker off, wait 10 minutes, check it is clean and clear, press RESET, power back on. King WHF Leave the heater off for 15 minutes, then look for anything on or near it. Marley Smart Series Wait for the red light to flash, then hold POWER and UP for 1.5 seconds. Trips more than once a day: Cadet says the heater must be replaced.
The overheat reset as each manual gives it. If your heater is not one of these, its own manual has the steps.
Check 1Free, two minutes

Check the thermostat and the breaker first

The thermostat. Cadet’s Com-Pak instructions are to turn the knob fully clockwise, then back counterclockwise once the room is warm. Its list for a heater that does not run starts with a thermostat set too low.

A digital Cadet Energy Plus. Cadet lists the heater sitting in FAN mode at 0 as a reason it does not heat or blows cold air: press the mode button to switch back to HEAT. A temperature lock can also keep it low.

The breaker. Cadet says electric heaters must be on a circuit used only for heaters. If its breaker is off, turn it back on. If it trips again straight away, Cadet’s causes are the wrong supply voltage, an overloaded circuit, a short circuit or a faulty breaker, and it says not to reset the breaker until any short is repaired: a breaker that keeps tripping.

Check 2Free, 10 to 20 minutes or more of waiting

Reset the overheat safety the maker's way

Cadet Com-Pak and Com-Pak Twin. Cadet says the manual power reset limit opens when the heater gets too hot, and it can be reset at the thermostat or the breaker. Turn the thermostat below room temperature, wait at least 20 minutes, fix whatever caused it, then turn the thermostat back up. Cadet says the standard built-in thermostat has no off position, so if the fix means taking the grill off, use the breaker way instead. If it does not come back on, turn its breaker off, wait at least 20 minutes, fix the cause, then turn the breaker and the thermostat back on. Cadet recommends the breaker method if the room is below 45°F.

Why the wait matters on a Com-Pak. Cadet says restoring power, even briefly, heats the limit again even if the heater does not come on, so the 20 minutes starts over every time the power goes off and on.

Cadet Energy Plus. Turn the power off at the main panel, allow 10 minutes to cool, make sure the heater is not blocked and is clean, push the reset button, and restore the power.

King WHF. King says its Smart Limit Protection stays off until the heater is turned off for fifteen minutes. Check for anything on or near the heater, and if it shuts off again, turn it off at the breaker and check for a failed fan motor or dirt and lint on the element.

Marley Smart Series. A red light, a beep and ES flashing in turn with the temperature mean the thermal limit has tripped and the buttons are locked. Marley says that once it cools, the red light flashes, and holding the POWER and UP buttons for 1.5 seconds resets it. If it shows E1, E2, ES on its own, or ES with E1 or E2, Marley says that is a fault: turn the power off at the main panel and call its technical support.

If it will not reset at all. Cadet says the Com-Pak also has a backup over-temperature fuse that opens in a severe overheat, and then the heater must be repaired or replaced. Marley says of its one-shot backup protector: if it opens, the heater has to be replaced. Cadet, King and Marley all say never to tamper with the overheat limit, and King and Marley say never to bypass it.

Check 3Free, every six months

Clean it, with the power off

Why. Cadet says the limit typically trips because the heater is blocked or needs cleaning, and lists dust and lint inside as one cause of smoke or a burnt smell. Cadet says to clean its heaters at least every six months; King says once a year.

Cadet’s steps. Let the heater cool, then turn the power off at the breaker before removing the grill. Cadet warns this is to prevent serious shock, burns or death, and says to lock or tag the panel door so nobody turns it back on. Cadet also warns breakers are often not marked correctly, so make sure the power is really off before you reach in, and to call a qualified electrician if you are not comfortable doing this. Holding the fan so it does not bend, blow the debris out through the element with a hair dryer or a vacuum on its blow setting without touching the element, and put the grill back before turning the power on.

Both Cadet guides. Cadet adds washing the grill in hot soapy water and drying it, and vacuuming the fan without touching the element. Cadet says never to oil the motor.

On a Marley Smart Series. Marley’s owner cleaning is the outside only. Turn the power off at the main panel first, because Marley notes power is still live to the heater when its POWER button has turned it off. Once it is cool, vacuum the grill openings with a brush attachment and wipe the grill with a damp cloth. It says a qualified service person should clean inside it at least once a year.

Painting the wall. Cadet’s Com-Pak guide says the warranty is void if anything is sprayed on the element or blower, and to mask the heater when walls are painted or textured. Cadet also says not to use the heater where paint or other flammable vapors or liquids are used, because it has hot and sparking parts inside.

Check 4

Keep the front clear

KEEP IT CLEAR, SEEN FROM ABOVE

3 ft in front

6 in 6 in

Cords, curtains, furniture and anything that burns 3 ft front, 6 in sides Never behind a door or below a towel bar Not above a tub or sink or in a shower; 2 ft away is best Cadet's numbers for its Com-Pak. Follow the numbers in your own heater's manual.

Cadet's clearances for its Com-Pak, seen from above. Your own heater's manual has the numbers that apply to it.

The makers’ numbers. Cadet says to keep cords, curtains, furniture and other things that can burn at least 3 feet from the front of a Com-Pak and 6 inches from its sides, and Marley gives the same 3 feet for the front. King says its heater must not be installed less than 6 inches from a side wall or the edge of a door. The makers all say extreme caution is needed when a heater is used by or near children, and Cadet says to keep all foreign objects out of it.

Where it must not be. Cadet says never in a floor, below a towel bar, behind a door, or anywhere its air can be blocked, and never directly above a bathtub or sink or in a shower area. It recommends at least 2 feet from them, and says the Energy Plus must be on a GFCI protected circuit in a bathroom.

If it keeps tripping. Cadet’s Energy Plus chart gives blocked airflow as the reason: remove the obstruction and keep the clearances. Cadet says a heater whose safety trips more than once a day must be replaced, and Marley says not to keep using a heater that keeps tripping after being reset. King says to turn the power off and have a heater whose limit keeps shutting it off checked by a qualified electrician, and Marley recommends an electrician’s check if it tripped with nothing blocking it.

The fan runs but the air is cold

Give it a moment. Cadet says the element needs a few moments to reach its working temperature.

A twin heater on half power. Cadet says the Com-Pak Twin has two heating units, each with its own overheat control. If one trips, the heater runs at half output until that unit is reset.

The wrong voltage. Cadet lists a supply voltage that does not match the heater’s label, an electrician’s check.

A failed element. On the Com-Pak, Cadet says to replace the element. On the Energy Plus, it says to replace the heater.

Other things the manuals list

The element heats for a moment, then stops, and the fan never turned. Cadet’s causes are a jammed fan or a failed motor. With the breaker off, remove anything jamming it, reset the limit, and if it still will not run, the heater needs repair or replacement.

It will not shut off. Cadet says the room may lose heat faster than the heater can make it: close doors and windows. Or the thermostat may be faulty: set it to its lowest setting, and if the heater still runs after two minutes with the room above 50°F, replace the thermostat. On the Energy Plus, a slow fan and low heat once the room is warm is its normal energy saving mode.

A smell the first time. Cadet says a new heater can smoke as the element burns off residue from manufacturing, usually gone within several hours. King says to open the windows until it stops.

What each one costs

The step Cost
Thermostat, breaker, overheat reset Nothing
Cleaning out the dust and lint Nothing
A new element or fan motor The part, fitted by a service person
Wiring, voltage or a breaker that trips at once An electrician’s visit
A recalled heater Apex72: a free new heater, installed at no cost. Old Cadet and Encore: CPSC lists no remedy now

Questions people ask

How do I reset an electric wall heater?

It depends on the make. Cadet’s Com-Pak resets at the thermostat or the breaker after at least 20 minutes off, King’s WHF after 15 minutes off, and Marley’s Smart Series with the POWER and UP buttons once its red light flashes. Fix what caused it first, usually dust or something blocking it, and turn the breaker off before you take the grill off to clean it.

Does a Cadet wall heater have a reset button?

The Energy Plus does: turn the power off at the panel, wait 10 minutes, check it is clean and clear, then push it. The Com-Pak has no button in its manual; it resets at the thermostat or the breaker.

Why does my wall heater keep shutting off?

Its overheat safety is tripping, usually because it is blocked or full of dust and lint, Cadet says. Clean it with the power off and keep the front clear. Cadet says a heater that trips more than once a day must be replaced.

Why is my wall heater blowing cold air?

Cadet lists a heater still warming up, a Com-Pak Twin running on one unit, the wrong voltage, a failed element, and on the Energy Plus, the heater left in FAN mode.

Is my Cadet wall heater recalled?

On an old Cadet or Encore, the model is on a label behind the grill, so turn the breaker off first: CPSC lists models FW, FX, LX, TK, ZA, Z, RA, RK, RLX, RX, RW and ZC. On an Apex72, CPSC says the model and date show on the rating label through the bottom of the air outlet grill: HW128, HW132 and HW151 made March 1, 2021 through February 29, 2024, and HW162, HW162BP5, HW168 and HW168BP5 made before March 1, 2024.

Can an electric wall heater go in a bathroom?

Cadet says never directly above a bathtub or sink or in a shower area, recommends at least 2 feet away, and says its Energy Plus must be on a GFCI protected circuit in a bathroom.

The other electric heat guides: a wall heater making noise, an electric baseboard heater not working, a baseboard heater making noise, a space heater not working and an electric heater that smells like burning.

Sources: Cadet Com-Pak and Com-Pak Twin owner's guide, Cadet Energy Plus owner's guide 720065, King Electrical WHF Series installation and troubleshooting, Marley Engineered Products Smart Series wall heater instructions 5200-11074, CPSC recall 00-070 (Cadet and Encore in-wall heaters, 2000) and CPSC recall 24-360 (Cadet Apex72 heaters, 2024)