On Rheem's three stage RP17, identify whether the wall control is EcoNet or a conventional thermostat. The RP17 manual gives conventional controls a B heating signal and a timed change from low to intermediate compressor speed. A quiet start or unchanged blower sound needs that context before a part is blamed.
A Rheem heat pump not heating after a thermostat change needs a look at how the thermostat is controlling it. On the three stage RP17, Rheem’s installation manual describes two control arrangements with different ways of requesting heat and compressor speed.
You can identify the arrangement and describe what the system does without opening the outdoor cabinet. That gives the installer something more useful than a request to replace whichever part sounds quiet.
Before you start
What to carry: a phone, a torch and the paperwork from the installation or recent thermostat work. Use an accessible exterior label or your records for the full outdoor model.
Which Rheem? This page follows the three stage RP17 in manual 92-105074-05 Rev. 05. It does not cover an RP17H side discharge unit simply because its name begins with the same letters.
Gas or electric? Rheem says this RP series can be installed with an air handler or a gas furnace. Include the indoor equipment in your report, particularly if another source of heat is still warming the house.
Renting? Send the findings to whoever maintains your heating. The observations below do not require access to wiring.
Rheem directs this installation manual to qualified, licensed service personnel and requires all power disconnected before maintenance. Keep the service panels closed, including when you want a board reading.
Do not bridge thermostat terminals or use the outdoor TEST button to obtain heat. Rheem says its test mode can energize the unit without a thermostat call. Leave voltage measurements, wiring changes and refrigerant work to service.
Start with the control that is actually installed
Identify EcoNet or conventional control
Rheem’s RP17 manual allows an EcoNet communicating control center or a conventional 24 volt thermostat. It says some comfort features are unavailable with conventional control, and the outdoor fault history is not available at that thermostat.
Check the name of your wall control. If it was replaced, keep the old control name with your installation records.
An empty fault screen on that replacement does not rule out an outdoor problem. For an accessible EcoNet alert, the RP17 error code guide explains the messages separately.
Report cooling that works but heating that does not
For conventional RP17 control, Rheem identifies B as the heat pump operation connection. Its heating test instructions require a 24 volt B signal as well as the compressor demand. That is a detail for the installer to verify when a replacement thermostat runs cooling but fails to provide heat.
Tell them whether cooling worked before the heating complaint, and whether any thermostat setup or wiring changed. Ask them to confirm the heating changeover configuration against this RP17 diagram and the replacement thermostat’s instructions.
Do not choose a wire by its color or move it to a terminal that happens to share a letter. Your useful check ends at describing the symptom and identifying the installed control.
A change in compressor speed may not change the blower sound
Give a conventional thermostat's heating call time to develop
Rheem gives the conventional two stage thermostat a specific RP17 sequence. With only Y calling, the compressor runs at its low speed for 15 minutes, then moves to intermediate speed if that call continues. A Y plus Y2 demand requests the maximum speed allowed by the model data at the outdoor temperature. Rheem also allows a higher compressor speed below 32 degrees F than above freezing.
The same manual says indoor airflow does not change at that timed move from low to intermediate speed. Listening at a vent will therefore miss that change. Tell service whether the room temperature is recovering, rather than reporting that no extra fan noise means no extra compressor output.
Rheem makes this timing specific to conventional control. In an EcoNet communicating installation, the control requests the three compressor speeds according to building demand. Do not use the conventional 15 minute sequence as a test for an EcoNet installation.
Separate a restart wait from a heating failure
Observe one uninterrupted request, then pass on the result
Rheem describes a four minute protection delay between RP17 compressor operations. Let that interval pass after a stop without repeatedly changing the operating mode. The four minutes describe compressor protection, rather than a promise that a cold house will be comfortable within that time.
If heating remains absent, send service the model, control name, room temperature, target and any accessible alert together. Add whether air moves indoors and whether you can hear operation outdoors from a safe position.
For an RP17 using EcoNet, Rheem says indoor airflow depends on the indoor equipment and installer settings. A blower adjustment is therefore a setup check for the technician, rather than a reason to start changing installer menus yourself.
What each one takes
| Finding | Work involved |
|---|---|
| Trouble began with a replacement thermostat | Installer verification of the RP17 heating signal and thermostat configuration |
| No visible fault on a conventional thermostat | Outdoor diagnostics by service if the heating complaint continues |
| Unchanged blower sound during a continuing Y only call | Checking the heating result, with the RP17 staging sequence in mind |
| No recovery after compressor protection has elapsed | Diagnosis using the model, symptoms and available control information |
Questions people ask
Does three stage mean I need three thermostat heating buttons?
Rheem describes a conventional two stage thermostat controlling the RP17’s low and intermediate speeds through the timed Y only sequence. The outdoor control handles that intermediate step. Rheem also allows a higher compressor speed below freezing.
Does EcoNet use that same timed step?
No. Rheem says the communicating arrangement requests each of the three compressor speeds according to demand.
Can the indoor fan tell me which compressor stage is running?
Not reliably on this RP17 arrangement. Rheem explicitly says the indoor airflow stays unchanged at the conventional low to intermediate transition.
Is this a guide for a Rheem heat pump water heater?
This page concerns the RP17 outdoor unit used for room heating. For water heating, use the Rheem heat pump water heater guide.
Where can the installer find the document used here?
Rheem hosts RP17 installation instructions, revision 05. Page 24 describes conventional control; pages 40 and 41 describe protection and staging.
The other heat pump guides: checking the heating result, an outdoor unit that stays silent and winter ice that does not clear.
Sources: Rheem RP17 three stage heat pump installation instructions 92-105074-05 Rev. 05, safety page 3 and control descriptions pages 24, 40 and 41; saved in data/sources/rheem-heat-pump-not-heating/rp17-install.pdf
By



