Amana Heat Pump Error Codes: ASZC18 and Code 04

Amana Heat Pump Error Codes: ASZC18 and Code 04
Short answer

For the Amana ASZC18 covered here, the control version matters. The PCBHR104 chart calls 04 a locked rotor fault and distinguishes pressure trips from L1 and L2 lockouts. Keep the thermostat wording with the number. This is a split system guide, not a PTAC or S-series code list.

Amana heat pump error codes need the model, the control version and the complete message. In Amana’s ASZC service literature, 04 is a locked rotor fault, but the possible causes include the run capacitor, wiring and low supply voltage as well as the compressor itself.

This page covers the ASZC18 split heat pump listed in service manual RS6200007r5, using its PCBHR104 display chart. Match the installed control before applying the displayed codes below.

Before you start

What to carry: a torch, your installation paperwork and a phone to record any thermostat message. Use the outdoor model number from an accessible label, without removing a service panel.

Which machine? A split system has a separate outdoor unit and indoor equipment. If the message comes from a room unit through the wall, use the Amana PTAC code guide. A gas furnace’s message belongs in the Amana furnace guide.

Renting? Give building maintenance the model, message and whether you selected heating or cooling.

The outdoor control is a service compartment.

Amana’s installation manual warns that multiple power supplies may be present and requires all power disconnected before service. It reserves installation, adjustment and repair for trained personnel. Do not open the cabinet to reach the display, probe terminals or test a capacitor.

The same manual warns against repeatedly resetting a breaker or replacing a fuse without correcting the problem. If you have already tried that and it trips again, leave it for service.

Keep the board code and thermostat message together

ASZC18 / PCBHR104: preserve the messageA04LOCKED ROTORThermostat code 04BoardBL1LPS LOCKOUTThermostat code 01Board
Amana's PCBHR104 chart pairs the board code with the ComfortNet thermostat message. An existing service photo can supply the board code; opening the outdoor cabinet is not an owner step.

Check 1

Record the whole message, including letters

Amana’s chart uses letters as well as numbers. Its PCBHR104 table distinguishes a board showing L1 from one showing 01, even though the ComfortNet thermostat can report code 01 for both.

The accompanying words help: the table pairs L1 with LPS LOCKOUT and a pressure trip with LPS OPEN. Preserve those words when reporting the problem, rather than reducing everything to “error one.”

If you only have a thermostat number, give the service company exactly that. They can identify the board and its stored condition. Do not choose a replacement part from a two digit message alone.

Code 04: locked rotor needs electrical diagnosis

Check 2

Treat 04 as a fault to investigate, not a compressor order

Amana’s PCBHR104 table describes 04 with the compressor and outdoor fan off, following four consecutive compressor protector trips with an average run time between trips below 15 seconds.

Its possible causes are seized compressor bearings, a failed run capacitor, faulty run capacitor wiring and low line voltage. A technician checks compressor operation, the capacitor, connections and supply voltage to separate those possibilities.

Amana’s service table includes a control power cycle to clear this fault. That belongs after diagnosis, rather than becoming a repeated attempt to force the unit to start.

Pressure trips and pressure lockouts

Check 3

Keep 01, 02, L1 and L2 separate

Amana’s PCBHR104 chart assigns 01 to a low pressure cutout trip or low side fault. It assigns 02 to a high pressure cutout trip or high side fault. L1 and L2 identify the corresponding pressure lockouts.

Board display Amana’s PCBHR104 description What helps the service visit
01 Low pressure trip or low side fault Full thermostat wording and operating mode
L1 Low pressure cutout lockout after three trips within the same thermostat demand Whether the fault keeps returning during the same demand
02 High pressure trip or high side fault Whether the outdoor fan was running when observed
L2 High pressure cutout lockout after three trips The original message before any reset

Amana’s L1 row lists low refrigerant charge, a liquid line restriction, indoor blower failure and an extremely low indoor thermostat setting among possible causes. Its high pressure rows include an obstructed outdoor coil or an outdoor fan that is not running.

Leave refrigerant and pressure switch checks to the technician. Tell the technician which mode was selected so the investigation fits the actual operating condition.

Owner checks that do not need an open cabinet

Check 4

Check the settings and accessible airflow path

Amana’s homeowner maintenance section says to confirm the thermostat setting, check the filter and look for blocked indoor air inlets and outlets. Move furniture or curtains that cover those openings.

For an accessible filter, turn the system off and follow the indoor equipment’s filter instructions. Amana says to replace disposable filters and clean reusable ones as required. Refit the filter and any cover before operation; its manual says never to run the system without a filter.

Outside, Amana allows removal of obstructions that can be removed safely. Leave the cabinet closed and keep your hands clear of the fan. The manual reserves outdoor coil cleaning for a qualified servicer because the tubing can be punctured.

If there is simply no response after changing a setting, Amana’s owner section allows 15 minutes for a possible automatic delay. That waiting advice is not a way to clear a known 04 fault or a repeatedly tripping breaker.

Some display messages describe normal operation

PCBHR104: operating messages and airflow faultsOperating messagesP1Low heatP2High heatdFDefrostAirflow faultsb0No indoor airflowb9Inadequate airflow
For PCBHR104, Amana lists P1 and P2 as heating stages and dF as defrost. Its b0 and b9 messages concern indoor airflow. Keep lowercase letters in the report.

Amana’s PCBHR104 chart calls P1 low heat, P2 high heat and dF defrost. Seeing one of those messages is different from finding a fault code.

The same chart defines b0 as no indoor airflow and b9 as inadequate airflow. If you have already completed the accessible filter and opening checks above, the next step is a blower and airflow assessment. A heating stage message alone cannot explain a house that remains cold.

What each one takes

Task Work involved
Identify model and thermostat message Paperwork and observation, with no open service panel
Restore accessible airflow Basic filter care and removing obstructions
Investigate 04 Electrical and compressor checks before selecting a part
Investigate a pressure lockout Professional refrigerant, airflow and control diagnosis
Clean the outdoor coil Qualified service under the maker’s owner instructions

Questions people ask

Where is the Amana heat pump error codes PDF?

The saved source is Amana / Goodman service manual RS6200007r5, June 2016. Despite the download filename, it is a technician service manual. The PCBHR104 summary is on page 53, with detailed rows following it.

What does Amana heat pump code 43 mean?

The PCBHR104 summary used here does not list 43. Keep the full message and model for the technician rather than assigning a definition from another Amana product.

Does this cover an Amana S-series or AVZC20?

No. This page uses the ASZC18 service literature and named control. An S-series or AVZC20 needs its own diagnostic chart, even if its thermostat looks similar.

My room heat pump shows L6. Which guide should I use?

For a through-wall PTAC, go to the Amana PTAC guide and match its covered series. Keep the equipment type with the message; a letter and number by themselves are not enough.

Can the heat pump display a code while still running?

Yes. Amana’s chart includes operating messages such as P1 and P2 alongside faults. Give the exact message and the actual symptom, rather than assuming every illuminated display is an error.

The other heat pump guides: heat pump not heating, an outdoor unit that will not run and Amana room unit codes.

Sources: Amana / Goodman ComfortNet Service Instructions RS6200007r5 (June 2016), ASZC18 product identification page 11, PCBHR104 chart pages 53, 56 to 58; Installation and Operation Manual IO-348N, pages 1, 20 and 23. Maker-authored PDFs saved from The AC Outlet.