Empire Wall Furnace Troubleshooting: GWT Pilot and Vent

Ray BennettBy Ray Bennett · Updated 22 October 2026 · 7 min read · Checked against the maker’s manual
Empire Wall Furnace Troubleshooting: GWT Pilot and Vent
Short answer

On Empire's GWT-50W-2, the pilot control and the manual reset vent safety switch do different jobs. A pilot that drops out needs the lighting sequence, flame and thermopile checked. A vent safety trip needs a venting investigation. Use this model's ten minute gas clearing wait, not another heater's timing.

Empire wall furnace troubleshooting starts by separating the pilot control from the vent safety switch. On the GWT-50W-2 gravity vented dual wall furnace, Empire says the vent safety switch needs a manual reset and can stop the main burner because of improper venting or a blocked flue.

That matters if you have read our general gas wall heater guide, which follows a Williams Forsaire. This page uses Empire manual 37410-6-0620 for the GWT-50W-2. Its lighting wait, thermopile readings and vent protection belong to that model.

A Rinnai EX38CT uses different controls. Its gas heater code guide covers that model’s display.

Before you start

What to carry: a torch, the furnace’s lighting label and a way to record the full model and fuel type. Describe whether the pilot never lights, goes out when the knob is released, or stays lit without main burner heat.

Gas or electric? This is a gas wall furnace. Empire’s lighting instructions include electrical isolation if applicable, so account for any powered accessory as well as the gas control.

Natural gas or propane? Check the rating plate. Empire’s propane safety section says people who are not qualified must not light pilots, service or adjust appliances on a propane system. Ask the gas supplier for help in that case. Empire also says not to light, service or adjust a propane appliance where other smells could hide a gas leak.

Renting? Give your maintenance contact the model, fuel and symptom. A photograph of an accessible label is more useful than a guess about which part has failed.

Stop for gas odor, water damage or a control that sticks.
Empire says to leave immediately if you smell gas. Do not light anything, touch switches or use a phone inside. Immediately call the gas supplier from a neighbor’s phone and follow its instructions; call the fire department if the supplier cannot be reached.

Empire permits only hand pressure on the gas knob, never tools. If it will not turn or push in by hand, arrange service. If it fails to pop up when released, stop and immediately call a qualified technician or gas supplier.

Do not use a furnace that has been under water. Empire says to call a qualified technician immediately to inspect it and replace any control system parts or gas controls that were under water. Its safety instructions also prohibit operation without the outer casing and require guards replaced after service.

Empire says to keep people away from hot surfaces, supervise young children, and keep clothing and other flammable materials off and away from the heater.

Empire warns that tampering with the vent safety system or using an improperly vented furnace can cause carbon monoxide poisoning. Leave casing removal, burner work, gas adjustments and safety switch diagnosis to qualified service.

Which control stopped the heat?

GWT-50W-2: TWO DIFFERENT CONTROLS A B A Vent safety switch On the draft diverter, behind the casing. A manual reset safety for the vent path. B Gas control knob Used for OFF, PILOT and ON. Follow this furnace's lighting label.
On Empire's GWT-50W-2, the vent safety switch is on the draft diverter. It is separate from the gas control used during pilot lighting. Locations are schematic, based on Empire's figure 8.
Check 1An observation and a service report, with no parts needed

Describe the flame that went out

Empire’s troubleshooting page separates four complaints: a pilot that cannot be lit, one that drops out when the control is released, one that fails during normal operation, and a main valve that does not open on a heat request.

Use what you have already observed during normal operation or lighting. Do not remove the casing and run the furnace to collect a closer view.

The burner stopping does not by itself identify a weak pilot generator.

The pilot lighting details that belong to this model

Check 2An operating check, or help from the gas supplier

Compare your attempt with Empire's complete lighting label

Use the complete label on the furnace or page 13 of the matching manual. For propane, the qualification rule above applies. If the label is missing or you cannot follow it safely, leave lighting to the gas supplier or service person.

Empire’s sequence starts with the gas odor checks, electrical power off if applicable, and the control access panel removed. The knob is pushed slightly in and turned to OFF without forcing it.

The next wait is ten minutes before checking for gas again, including near the floor. Use this model’s timing rather than another heater’s procedure. Gas odor at that point means stop and follow the emergency instructions.

Empire then locates the pilot at the front of the main burner, turns the knob to PILOT, and holds it fully in while lighting with a match. The knob stays in for about one minute after the pilot lights, then should pop up when released. If the pilot goes out, Empire says to repeat steps 5 through 9, including the full ten minute wait and gas odor check.

Once the pilot holds, Empire finishes with the knob at ON, the control access panel replaced, and applicable electrical power restored. If it will not remain lit after several tries, the manual says to turn the knob OFF and call for service.

Pilot outages and the thermopile

Check 3Pilot inspection and millivolt measurements by service

Keep the flame and test conditions together

Empire calls the pilot generator in this manual a thermopile. Use that part name and the model number when discussing a repair, rather than ordering a generic thermocouple from a symptom alone.

For a pilot that drops out when the knob is released, Empire first checks the lighting procedure and whether the flame extends past the thermopile. Its flame drawing shows blue flame surrounding the thermopile just below the tip.

If the pilot cannot light despite gas being available in its supply tubing, Empire lists a possible spider web restriction at the pilot opening or burner. Leave cleaning and adjustment to service; that is not a reason to poke an opening with a needle.

Empire’s replacement threshold is below 300 millivolts with the wall mounted on/off device or remote bulb turned OFF. Its system check on page 12 also gives separate readings with the heater off and on. A reading taken under another condition cannot be compared directly with that replacement threshold.

For pilot loss during normal operation, Empire instead checks gas input and thermopile output while running. If output decreases during operation, the manual says the gas control may be defective. That still needs a diagnosis.

GWT-50W-2: THE TEST CONDITION MATTERS A 400 to 450 millivolts Across thermopile terminals, heater OFF. System check, Empire page 12. B 150 to 250 millivolts Across thermopile terminals, heater ON. System check, Empire page 12. C Below 300 millivolts Replacement threshold with wall device or remote bulb OFF. Pilot fault test, Empire page 15. Service measurements.
Empire's GWT-50W-2 service readings depend on the test conditions. The below 300 mV replacement threshold specifically requires the wall on/off device or remote bulb OFF.

The pilot stays lit, but the room gets no heat

Check 4Control circuit tests before replacing the gas valve

Report the on/off device's setting

After successful lighting, check whether you left the gas control at ON as the label requires, and whether the installed room control is asking for heat. Do not change its wiring to make a heat request.

For a main valve that does not open when the on/off device is on, Empire lists thermopile output, broken device wires and a defective device. Its page 12 describes a millivolt control designed for a self generating system, not a line voltage or low voltage AC circuit.

Mention any recent switch, remote or thermostat work. That helps the technician check the actual control fitted to your furnace rather than assuming every wall control is interchangeable.

Check 5Venting and safety switch inspection

Give a vent safety trip its own investigation

Empire places the manual reset vent safety on the draft diverter behind the outer casing. Its page 14 explains that improper venting or a blocked flue can shut gas off to the main burner through this switch.

The manual requires a qualified service person if the switch continues to stop the burner. The listed checks are venting, vent pipe blockage and the switch itself. Leave access and reset to that visit so the reason for the trip is addressed.

Keep the surroundings clear. Empire specifically prohibits objects that obstruct combustion and ventilation airflow. Empire requires inspection by a qualified service person before use and at least once a year.

What each one takes

Finding Work involved
Incorrect lighting sequence Following this model’s label, with gas supplier help where needed
Pilot drops out on release Flame coverage and thermopile testing under the specified conditions
Pilot fails while running Gas input and operating millivolt checks
Pilot remains, main burner stays off Room control, wiring and thermopile diagnosis
Vent safety shutdown Venting, blockage and switch inspection before normal use resumes

Questions people ask

Where is the Empire GWT-50W-2 manual?

Use Empire’s 37410-6-0620 manual. The English lighting procedure is on page 13, vent safety on page 14 and troubleshooting on page 15.

Does this chart cover Empire DV wall furnaces?

No. The model used here is GWT-50W-2. Get the matching DV manual before carrying over a control location, pilot procedure or electrical reading.

Can I adjust the main burner’s air shutter?

Empire says the GWT-50W-2 burner has no primary air adjustment. Its flame and gas input checks belong with service, rather than an adjustment borrowed from another heater.

Does a glowing pilot prove the thermopile is good?

No. Empire still lists thermopile output among the checks when the main valve fails to open. The specified service measurements tell more than the presence of a flame.

Should I fit a different gas control first?

Empire’s chart tests the pilot system and control circuit before selecting a repair. Give the dealer the full model, serial number and gas type so any proposed part matches the furnace.

The other wall heater guides: Williams direct vent troubleshooting, wall heater noises and Rinnai wall heater codes.

Sources: Empire Comfort Systems GWT-50W-2 Installation Instructions and Owner's Manual 37410-6-0620, pages 1, 3, 4 and 12 to 15.