LG Mini Split Error Codes: What CH05, CH38 and CH67 Mean
LG shows a fault as CH and a number, and its own first step for nearly every code is to switch the power off for five minutes. CH05 and CH53 mean the indoor and outdoor units are not talking, CH07 two rooms in different modes, CH10 and CH67 a fan that cannot turn, CH61 running too hot, and CH38 low refrigerant, which no reset will fix.
LG mini splits report a fault as CH followed by a number, on the unit’s display, on a wired wall controller, or as a blinking light. LG’s own first step for nearly every code is the same five minute reset, and it tells you which codes belong to the installer instead.
Everything on this page comes from LG’s own material: the LG USA help library guide to air conditioner error codes, updated in February 2026, and the troubleshooting tables in LG’s Single Zone Art Cool Premier wall mounted installation manual. LG says its help guide covers all its air conditioners, so parts of it describe window and portable units rather than mini splits.
Before you start
What to carry: the remote, a torch and a pen. Five minutes, plus a five minute wait with the power off.
Gas or electric? A mini split is all electric, a heat pump that heats and cools.
Write the code down first. LG’s manual says the code stops showing once the fault clears, and if two faults happen at once, the lower number shows first.
Think about when it started. LG splits several codes by timing. Right after installing or moving the unit points at the installation, and during normal use it is often a power blip.
A refrigerant leak on a newer system. LG’s R32 units use a refrigerant LG describes as slightly flammable. If you suspect a leak, LG says to turn off anything with a flame, ventilate the area, contact the installer and not run the unit until the leak is repaired: signs the refrigerant is leaking.
The reset LG starts with
Do the five minute power cycle
Power off. Turn off the breaker for the air conditioner, or unplug it if it has a plug. LG says the fault may be a temporary one caused by unstable power.
Wait five minutes. LG’s instruction for nearly every code is five minutes, not a quick flick of the switch.
Power on and start it with the remote. If the same code or symptom returns, LG says the unit needs a technician.
CH61 needs this reset. LG says the overheating code does not clear by itself, so the power cycle is how you clear it once the cause is fixed.
What each code means, from LG
LG’s help guide lists these codes, with the other names some models show them under.
| Code | Also shown as | What LG says it means | Check first |
|---|---|---|---|
| CH04 | FL | Condensate not draining from the indoor unit | Reset, then service |
| CH05 | E0, CH53 | Indoor and outdoor units not communicating | Reset |
| CH07 | None | Units set to heating and cooling at the same time | Set every unit alike |
| CH10 | E6 | Indoor unit fan | Debris at the fan |
| CH32, CH33, CH36 | None | Refrigerant or compressor problem: a power blip, or the outdoor unit’s compressor, drive or electronics | Reset; new install, installer |
| CH38 | F4 | Low on refrigerant | Installer or technician |
| CH54 | None | Reverse phase, after a power cut or electrical work | Reset the breaker |
| CH61 | P4, P6, P7, P8, CH34 | Overheating: the outdoor unit in cooling, the indoor unit in heating | Clear the outdoor unit, clean the filter |
| CH66 | None | Communication line or piping connection between the units | Reset; new install, installer |
| CH67 | EF | Outdoor unit fan | Debris or snow at the fan |
| CH90, CH91 | F4 | Protection during the test run | Installer |
| CH93 | None | Communication problem, often at the test run | The outdoor unit’s power |
| CH237, CH238 | None | Outdoor unit has no power, on newer models with a power cord for each unit | The outdoor unit’s plug and breaker |
The codes you can often clear yourself
Work the free check for your code
CH07: rooms in different modes. On a multi zone system, one outdoor unit cannot heat one room and cool another. LG says to set every unit to heating, or every unit to cooling or dehumidifying. Fan and air purifying modes can run alongside anything: why one head will not start on a multi zone system.
CH61 in cooling: the outdoor unit is too hot. LG says this often happens when hot air cannot get away from the outdoor unit. Clear anything piled up near it so the hot air can escape.
CH61 in heating: the indoor unit is too hot. LG names poor air intake, often a clogged or dirty filter. Clean the indoor unit’s filters: how to wash mini split filters.
CH10 and CH67: a fan. LG says to check for debris or snow around the indoor and outdoor fans and remove it. Switch off at the breaker before reaching near either fan.
CH93, CH237 and CH238: the outdoor unit’s power. Check the breaker for the outdoor unit and the disconnect switch beside it. LG adds that a plug-in unit belongs in a wall outlet, never a power strip.
CH05, CH53 and CH66 during normal use. LG treats these as a likely power blip first. Do the five minute reset.
The numbers on the board and the wired controller
LG’s installation manual lists the numbers behind the CH codes for its single zone wall units. They show on the indoor and outdoor control boards, on a wired wall controller if one is fitted, and in LG’s service software. LG’s example for reading the board lights is code 21: the green light blinks twice and the red light once.
| Code | What LG’s manual says |
|---|---|
| 1 | Indoor room temperature sensor |
| 2 | Indoor coil inlet pipe sensor |
| 4 | Float switch, on units fitted with one |
| 5 | Indoor unit cannot talk to the outdoor unit |
| 6 | Indoor coil outlet pipe sensor |
| 9 | Indoor unit memory (EEPROM) |
| 10 | Indoor fan motor locked |
| 12 | Indoor coil middle pipe sensor |
| 21 | DC peak, a fault in the compressor’s power module |
| 22 | AC input current too high |
| 23 | DC link voltage too low |
| 25 | Supply voltage too low or too high |
| 26 | Compressor not turning, or locked |
| 27 | Current too high between the AC and DC stages |
| 28 | Compressor DC voltage too high |
| 29 | Compressor current too high |
| 31 | Current sensor reading too low |
| 32 | Compressor discharge pipe too hot |
| 40 | Current sensor disconnected or shorted |
| 41 | Discharge pipe sensor |
| 44 | Outdoor air sensor |
| 45 | Outdoor coil middle sensor |
| 46 | Suction line sensor |
| 48 | Outdoor coil outlet sensor, on the liquid line |
| 53 | Outdoor unit cannot talk to the indoor unit |
| 60 | Outdoor board memory (EEPROM) |
| 61 | Outdoor coil too hot |
| 62 | Outdoor board heat sink too hot |
| 63 | Outdoor coil pipe temperature too low |
| 65 | Heat sink sensor |
| 67 | Outdoor fan motor locked |
LG notes that the outdoor unit’s codes show at both units, but the indoor unit’s own codes only show indoors.
When it needs a technician
Know when to stop
CH38 and F4. Low refrigerant. After installing or moving the unit, LG sends you to the installer to check the charge and the pipe connections. During normal use, LG’s step is one power cycle, then LG support if it returns.
CH32, CH33 and CH36. LG’s help library groups them with CH38 and F4 as refrigerant or compressor problems, from a temporary power issue to a fault in the outdoor unit’s compressor, drive, protection circuit or electronics. The same steps apply: the installer if it is new, one five minute reset in normal use, then LG support.
CH05, CH53, CH66 or CH93 that come back. LG’s own step after the reset is service. Right after an installation, these point at the wiring or piping, and the installer should come back.
CH90 and CH91. LG says these appear during the test run to protect the unit. After installing or moving it, the pipe connections need checking by the installer.
21 to 32, 60 and 62. The compressor, its power electronics and the outdoor board. That is sealed system and high voltage work.
The sensor codes. 1, 2, 6, 12, 40, 41, 44 to 48 and 65 are sensors read as disconnected or shorted. Usually the sensor, sometimes the board.
Questions people ask
What does CH38 mean on an LG mini split?
Low refrigerant. If it appeared after installing or moving the unit, LG says to call the installer. If it appeared during normal use, switch off for five minutes, and contact LG support if it returns. A reset cannot put refrigerant back.
What does CH32 mean on an LG?
LG groups CH32 with CH33, CH36, CH38 and F4 as refrigerant or compressor problems. Right after installation, call the installer. In normal use, switch off for five minutes, and contact LG support if it returns.
What does CH05 mean?
The indoor and outdoor units are not communicating. Some models show it as E0 or CH53. LG’s step is the five minute power cycle, then service if it persists.
My LG shows CH34 or CH35.
LG’s guide groups CH34 with CH61, the overheating code, so clear the outdoor unit and clean the filters. LG’s guide does not list CH35, and for any code it does not list, LG recommends a technician’s inspection.
Why is the light on my LG mini split blinking?
LG says the indoor unit’s indicator light blinks at two second intervals when an error occurs. Look for the code on the display or the wired controller, then do the five minute reset.
My display says EO. Is that the E0 fault?
Not always. LG notes that on some models the indoor display shows EO while the kW Manager feature is running, which is not a fault.
Will the code clear by itself?
LG says a code stops showing once its fault is resolved. CH61 is the exception LG names: it needs a power cycle to clear.
Sources: LG USA help library "Guide to Error Codes" (updated 23 February 2026), LG's help library article on codes CH05, CH32 to CH38, F4 and CH66 to CH93 (August 2026), and LG's Single Zone Art Cool Premier Wall Mounted Installation Manual