Home / Furnaces / Furnace Limit Switch: What Tripping It Means

Furnace Limit Switch: What Tripping It Means

Ray BennettBy Ray Bennett · Updated 2 October 2026 · 5 min read · Checked against the sources at the end
Furnace Limit Switch: What Tripping It Means
Short answer

A limit switch cuts the gas when the air leaving the furnace gets hotter than it should, which almost always means not enough air is getting through. So a tripping limit is a message about airflow rather than a broken part, and the filter is the first thing to look at every single time.

A limit switch is a small temperature sensor sitting where the warm air leaves the furnace, and it has one job. If that air gets hotter than the furnace is rated for, it shuts the gas off.

Which means a furnace that keeps tripping its limit is not usually a furnace with a broken switch. It is a furnace that cannot get rid of its own heat.

Before you start

What to carry: a new filter, a torch and a screwdriver. Twenty minutes.

Gas or electric? Both have one. On a gas furnace it cuts the gas valve. On an electric one it cuts the heating elements. The causes are identical because both are about airflow.

Watch one full cycle first. The signature is unmistakable once you have seen it: it lights, runs a few minutes, the burners go out, and the blower keeps running on its own for a while afterwards.

The line on this one is absolute. Never bypass a limit switch. Not with a jumper, not with a wire nut, not for one cold night. It is the device that stops a furnace running hot enough to crack its heat exchanger or set fire to what is around it, and a furnace with a defeated limit has nothing left watching it.

And know which switch you are pressing. If the button you found is down beside the burners rather than up on the cabinet, that is a rollout switch, and a tripped rollout means flame came out of the burner box. That one is never a reset and carry on.

Why it trips

WHAT A TRIPPED LIMIT IS TELLING YOU Air cannot get in a filter, a shut vent, a blocked return Less air over it the same flame, spread over less air The air runs hot hotter than the plate on the door allows The limit opens it shuts the gas the fan runs on It is not the fault. It is the message. Fix the air, and it stops tripping.
Four steps, and only the first one is a fault. Everything after it is the furnace protecting itself correctly.
Check 1Free, or the price of a filter

Airflow, in the order it is usually wrong

The filter. Every time, first. A clogged one starves the furnace of the air it needs to carry the heat away, and Carrier’s manual lists it first for a limit fault. While you have it out, check it is the right size and the right way round: which way the arrow goes.

Closed or blocked registers. Vents shut in spare rooms, a sofa across one, a rug over another. Every one you close raises the pressure and cuts the flow: closing vents in unused rooms.

The return. Furniture in front of the return grille, or a return that was always too small for the furnace fitted to it.

The blower wheel. A drum of small blades that fills with dust until it is spinning fast and moving very little: what a packed blower wheel looks like.

The blower speed. If somebody changed it during a repair and it never went back, the furnace has been running hotter ever since.

Where it is, and the reset

TWO SAFETY SWITCHES, VERY DIFFERENT NEWS the heat exchanger The limit, up top It watches the air leaving the furnace. It opens when that air gets too hot, which is airflow. Common, usually a filter, and it resets itself. The rollout, down by the burners It opens when flame comes out of the burner box instead of going up the flue. That is not airflow, it is combustion, and it means somebody out. Never press that one twice and walk away.
Two switches, two very different messages. Knowing which one you are looking at matters more than knowing how to press it.
Check 2

Find it before you touch it

The limit. On the cabinet above the heat exchanger, often on the wall of the blower compartment, usually a small round disc with two wires. Most are automatic, so they reset themselves once things cool down, which is why the furnace starts again a few minutes later and then does the same thing.

The manual kind. Some have a small button you press. Pressing it once is a test. Pressing it a second time is feeding a fault that nobody has found: what a reset button really is.

The rollout switches. Down at the burner end, usually with a red button, sometimes two or three of them. These open when flame rolls out of the burner box instead of going up the flue, which points at a blocked heat exchanger, a blocked flue or a cracked one. Do not reset one and walk away.

If it lights, runs, quits and repeats, that is the whole picture and it has a page of its own: time the burners and read it off the clock.

When the switch really has failed

Check 3

How to know it is genuinely the part

Limit switches do wear out, and after years of wear they can open below the temperature they are supposed to. The honest way to tell is to rule out everything else first.

Measure the temperature rise. A thermometer in the return and another in a supply vent, subtracted, compared with the band on the plate inside the door. If the rise is inside the band and the limit still trips, the switch is suspect: how to take that measurement.

Check it is the right part. Limits are rated for a specific temperature, printed on the body. A previous repair fitted with whatever was on the van will trip early forever.

And rule out the cheap stuff twice. A new filter, every register open and a clear return, for a week. If it stops tripping, you never needed a part at all.

Questions people ask

Can I just reset it and get through tonight?

Once, while you find the filter, yes. Repeatedly, no, because each trip is the furnace having already reached a temperature it should never see.

Why does the fan keep running after the burners stop?

That is correct and it is the furnace cooling itself down. The fan carrying heat away after a limit trip is the thing that stops the damage.

It only trips when the bedroom doors are shut.

Then you have found it. Shut doors cut the return path and starve the furnace, which is the same fault as a blocked filter: why a shut door changes so much.

How hot does the air have to get?

The plate inside the door gives a band, usually about thirty degrees wide, and the limit sits above the top of it. So a furnace tripping is running well outside what it was designed for.

Mine has three buttons by the burners.

Those are rollouts, not limits. Three of them opening means flame went somewhere it should not have, and that needs somebody out rather than a finger.

Is a tripping limit dangerous in itself?

No, it is the opposite. It is the protection working. What is dangerous is ignoring why it keeps happening, or defeating it.

Sources: Trane "Furnace Limit Switch Basics", Goodman installation instructions IOG-2009E for the *MSS9 and *CSS9 furnaces (primary, auxiliary and rollout limits), Lennox installation instructions 507323-01 for the ML180UH, Carrier 58SC0A/58SC1A installation, start-up, operating and service instructions (status code 33) and York installation manual 561276-UIM-A-0310 (temperature rise ranges)