No Air From the Vents: One Room or All of Them
Walk the house with a sheet of paper and hold it to every register. Nothing anywhere means the problem is at the box, and the panel switch behind the blower door catches a lot of people. Nothing in one room means that one branch, and a duct pulled off its boot in the attic is far more common than it sounds.
No air at the vents is one of the few complaints where five minutes of walking about tells you almost everything. The system either cannot make air, or it is making it and losing it on the way to you.
Those two have nothing in common, so the page splits at the top and you only need half of it.
Before you start
What to carry: a sheet of paper, a torch and a screwdriver. Twenty minutes.
Gas or electric? It makes no difference to the fan. A gas furnace, an electric furnace and an air handler all use the same blower to push air through the same ducts, so everything here applies to all three. What does change is where the blower lives, which is behind the lower panel on a furnace and behind the front panel on an air handler.
Set the fan to ON at the thermostat. That runs the blower whether or not anything is heating or cooling, which is exactly what you want while you test.
Never jam the door switch. There is a small plunger behind the blower panel that stops the fan running with the panel off. People wedge it with tape to watch the blower turn and then forget about it, which leaves a machine that can run with its door open for the rest of its life.
One room, or all of them
Paper at every register, then at the return
With the fan on ON, hold a sheet of paper flat against each supply register in turn. It should be pushed away firmly.
Nothing at any of them. The problem is at the box. Go to check 2.
Nothing at one, and the rest are fine. The problem is in that branch. Go to check 3.
All of them weak rather than dead. That is a third picture, further down the page.
Now do the same at the return, the big grille the system breathes in through. This is the test that gets skipped and it is the most useful one.
The return pulls hard, but nothing comes out anywhere. The air is being made and then lost between the two, which means a main duct has come apart somewhere you cannot see.
The return barely pulls either. The blower itself is the problem, not the ducts.
Nothing anywhere: start at the box
Is the blower actually turning?
Go and stand at the furnace or air handler with the fan set to ON and listen.
The panel. If it is silent, check the blower door is clicked properly shut. There is a plunger switch behind it and a panel resting in place rather than latched leaves the fan dead. This is a typical fault after somebody changes a filter, and it is free.
The switch and the breaker. The switch on the side of the unit looks like a light switch and gets turned off by mistake. Then the breaker.
The filter. A filter left in far too long collapses and sucks flat against its frame, which blocks nearly everything. Pull it out and try the fan without it for a minute. If the air comes back, that was your answer.
Ice on the coil. A coil frozen into a solid block stops air dead. Switch to fan only and wait. Carrier says heavy ice can take 4 to 8 hours or longer: why it ices and how to thaw it.
The small fuse on the board. A blown low voltage fuse leaves everything dead including the fan: where that fuse is and what blows it.
The blower wheel nobody looks at
There is one cause of weak air that rarely gets mentioned, and it is common on any system that has run for years with a cheap filter or no filter at all.
The blower is a drum with dozens of small curved blades round its rim. Each of those blades scoops air. As dust packs into the gaps between them the blades effectively disappear, and the wheel ends up spinning at full speed while moving a fraction of what it should.
It sounds normal, and nothing has failed. You have to take the panel off and look at it with a torch. If the gaps are filled with grey felt, that is your missing airflow, and cleaning it properly means pulling the blower out.
Nothing from one room
Follow that branch from the register backwards
The register itself. The lever on the front, which somebody closed last winter, or a register that has been painted over enough times to seize.
The damper at the other end. Many branches have a small lever on the duct near the air handler for balancing. They get set once, forgotten, and left the wrong way for a decade.
A crushed or kinked flexible duct. Flex duct is easy to bend past the point where it passes air, and storage boxes in an attic do it all the time.
A branch that has come off its boot. A common real fault behind one dead room. The duct pulls away from the fitting under the floor of the attic and the whole branch blows into the roof space instead. The tell is a room that sits at whatever the weather is doing while everywhere else is comfortable.
Something in the duct. Rodent nests, builders’ offcuts left at installation, and once in a while a child’s toy.
The far end of a long run. If that room has always been the weakest, it may never have had enough push to reach it, which is a balancing job rather than a fault.
Weak everywhere, rather than nothing
If every register gives you something but not much, the list is shorter.
The filter and the blower wheel above are the first two. After that it is the ducts themselves, because a system losing a large share of its air into an attic or a crawlspace feels exactly like a weak fan: how much gets lost on the way.
Two other things worth knowing. Registers closed in spare rooms raise the pressure in the ducts and push more air out of every leak, so it makes the rest of the house worse rather than better. And not enough return air starves the whole system, which is why a bedroom with its door shut and no return path never feels right.
If the blower speed was changed during a repair and everything has been weak ever since, that is worth asking about: what else lives in that box.
Questions people ask
It stopped right after I changed the filter.
The blower panel, almost certainly. Press it firmly until it latches, because resting it in place is not enough to hold the switch in.
One room is fine in summer and dead in winter.
That points at a damper rather than a blockage, because a genuine obstruction does not know what season it is. Somebody has been balancing the system.
The fan runs but the air feels weak and warm.
Then the fan is probably set to ON rather than AUTO, so it keeps blowing room temperature air between heating or cooling cycles. Put it back to AUTO and see.
How do I find a duct that has come off?
Go into the attic or crawlspace early in the morning with the fan running and listen. A disconnected branch is loud, and you usually feel the draught before you see it.
Should I close vents in rooms I do not use?
No. It raises the pressure in the ducts, pushes more air out of every leak and starves the coil, so it costs you more than it saves.
Nothing works at all, not even the fan.
Then it is not really a vent problem. Start with the five free checks on the machine itself: what to check when nothing happens.